MaintainX Asset Hub logo
EnterprisePricing
Quidel Cardiovascular

Quidel Cardiovascular Analyzer Triage Meter Pro

Need answers fast?
Explore the manual using AI.

Quidel Cardiovascular Analyzer Triage Meter Pro
Quidel Cardiovascular Analyzer Triage Meter Pro

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Quidel Cardiovascular Analyzer Triage Meter Pro

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Quidel Cardiovascular Analyzer Triage Meter Pro

Quidel Cardiovascular Analyzer Triage Meter Pro

Create an account to install this asset package.

Maintenance Plans for Quidel Cardiovascular Analyzer Model Triage Meter Pro

Integrate maintenance plans directly into your work orders in MaintainX.

Battery Replacement

Check mark

Battery Removal

Check mark

Turn off the meter

Check mark

Remove the battery cover from the bottom of the meter by sliding the cover in the direction of the arrow

Check mark

Remove the batteries

Check mark

Dispose of the batteries in compliance with local regulations

Check mark

Battery Insertion

Check mark

Insert four size AA 1.5-volt batteries into the battery compartment

Check mark

Ensure battery alignment

Check mark

Replace the cover to the battery compartment

Run this procedureArrow right

Analyzer Cleaning

Check mark

Exterior Cleaning

Check mark

Apply mild soap and water solution with a damp sponge or cloth to the exterior of the meter

Check mark

Wipe the meter dry using a soft cloth or absorbent tissue

Check mark

Ensure no water seeps into the printer

Check mark

Confirm the meter is not immersed in water or other liquids

Check mark

Device Track Door Cleaning

Check mark

Use a cotton swab dampened with isopropyl alcohol to clean the device track door

Check mark

Lift the door carefully with tweezers and clean both front and back of the door

Check mark

Ensure no tools, swabs, or cleaning materials are inserted into the device track

Run this procedureArrow right

Paper Replacement

Check mark

Changing Paper Between Functions

Check mark

Tear off any excess paper sticking out of the Quidel Triage MeterPro.

Check mark

Remove the paper compartment cover by pulling up on the cover as indicated by the arrow on the back of the cover.

Check mark

Remove unused paper or the empty paper spindle from paper compartment.

Check mark

Tear or cut a clean, straight edge to feed into the printer. Do not cut paper at an angle.

Check mark

Insert the new roll of paper into the paper compartment.

Check mark

Position the paper such that the paper will feed from under the roll.

Check mark

Insert the paper edge under the paper roller (platen) until it firmly seats or resistance is felt.

Check mark

Press the key to feed the paper.

Run this procedureArrow right

Battery Level Check

Check mark

Preparation

Check mark

Navigate to the MAIN MENU

Check mark

Disconnect the AC power supply

Check mark

Battery Power Check

Check mark

Press the key to attempt device ejection

Check mark

Is the Low Power Indicator flashing on the Main Menu?

Check mark

Battery Replacement

Check mark

Replace the batteries if the Low Power Indicator is flashing

Check mark

Battery Life Preservation

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

Explore Other Assets