MaintainX Asset Hub logo
EnterprisePricing
Mitsubishi

Mitsubishi Split-Type Air Conditioner MUZ-FH15NA

Need answers fast?
Explore the manual using AI.

Mitsubishi Split-Type Air Conditioner MUZ-FH15NA
Mitsubishi Split-Type Air Conditioner MUZ-FH15NA

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mitsubishi Split-Type Air Conditioner MUZ-FH15NA

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mitsubishi Split-Type Air Conditioner MUZ-FH15NA

Mitsubishi Split-Type Air Conditioner MUZ-FH15NA

Create an account to install this asset package.

Maintenance Plans for Mitsubishi Split-Type Air Conditioner Model MUZ-FH15NA

Integrate maintenance plans directly into your work orders in MaintainX.

Outdoor Unit Cabinet Replacement

Check mark

Remove the screws of the service panel

Check mark

Remove the screws of the top panel

Check mark

Remove the screw of the valve cover

Check mark

Remove the service panel

Check mark

Remove the screws fixing the conduit cover

Check mark

Remove the conduit cover

Check mark

Remove the screw of fixing the conduit plate

Check mark

Remove the conduit plate

Check mark

Remove the top panel

Run this procedureArrow right

Outdoor Unit Discharge Temperature, Defrost,Outdoor Heat Exchanger Temperature and Ambient Temperature Thermistor Replacement

Check mark

Remove the cabinet and panels

Check mark

Disconnect the lead wire to the reactor

Check mark

Disconnect the following connectors: CN671 (Defrost thermistor, discharge temperature thermistor and outdoor heart exchanger temperature thermistor)

Check mark

Disconnect the following connectors: CN672 (Ambient temperature thermistor)

Check mark

Pull out the discharge temperature thermistor from its holder

Check mark

Pull out the defrost thermistor from its holder

Check mark

Pull out the outdoor heat exchanger temperature thermistor from its holder

Check mark

Pull out the ambient temperature thermistor from its holder

Run this procedureArrow right

Outdoor Unit R.V. Coil Replacement

Check mark

Remove the cabinet and panels

Check mark

Disconnect the following connector: <Inverter P.C. board> CN602 (R.V. coil)

Check mark

Remove the R.V. coil

Run this procedureArrow right

Outdoor Unit Fan Motor Replacement

Check mark

Warning: Ensure the unit is powered off before starting the procedure

Check mark

Top panel, cabinet and service panel removed

Check mark

Inverter P.C. board connectors CN931 and CN932 disconnected

Check mark

Propeller fan removed

Check mark

Screws fixing the fan motor removed

Check mark

Fan motor removed

Check mark

Sign off on the fan motor replacement

Run this procedureArrow right

Outdoor Unit Compressor and 4-Way Valve Replacement

Check mark

Remove the top panel, cabinet and service panel

Check mark

Remove the back panel

Check mark

Remove the inverter assembly

Check mark

Remove the soundproof felt

Check mark

Recover gas from the refrigerant circuit until the pressure gauge shows 0 PSIG

Check mark

Detach the brazed part of the suction and the discharge pipe connected with compressor

Check mark

Remove the nuts fixing the compressor

Check mark

Remove the compressor

Check mark

Detach the brazed parts of 4-way valve and pipe

Run this procedureArrow right

Parts for Mitsubishi Split-Type Air Conditioner MUZ-FH15NA

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Compressor

SNB172FQKMT

Compressor

SNB172FQKMT

Compressor

SNB172FQKMT

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mitsubishi

Explore Other Assets