Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Lennox HVAC Unit EL16XC1-036
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly HVAC Unit Testing
General System Test
Turn on the air conditioner and check operating functions such as start-up and shut-off operation.
Note any unusual noises or odors.
Measure indoor temperature.
Measure outdoor temperature.
Measure system pressures as needed.
Refrigerant Charge Check
Check the refrigerant charge per the charging sticker information on the outdoor unit.
System Pressure and Airflow Verification
1 Yearly Indoor Unit Inspection
Electrical and Wiring Inspection
Inspect component wiring for loose, worn or damaged connections.
Confirm proper voltage of indoor unit.
Confirm proper amperage of indoor unit.
Air Filter and Blower Inspection
Inspect air filters in indoor unit.
Was the air filter cleaned or replaced?
Check the cleanliness of indoor blower.
Was the indoor blower cleaned?
1 Yearly Outdoor Unit Inspection
Electrical Inspection
Inspect component wiring for loose, worn or damaged connections.
Check for any rubbing or pinching of wires.
Confirm proper voltage of outdoor unit.
Confirm proper amperage of outdoor unit.
Fan and Blade Inspection
Check cleanliness of outdoor fan and blade assemblies.
Check condition of fan blades for cracks.
Clean or replace fan blades if necessary.
HVAC Unit Testing
Safety Precautions
Ensure the use of a regulator that can control pressure down to 1 or 2 psig (6.9 to 13.8 kPa) when using high pressure gas.
Verify that the leak detector is capable of sensing HFC refrigerant.
Ensure refrigerant is used and recovered responsibly to prevent personal injury or death.
Connect Gauge Set
Connect manifold gauge set
Test for Leaks
Prepare for leak test
Pressurize with dry nitrogen
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX