MaintainX Asset Hub logo
EnterprisePricing
Evoqua Water Technologies

Evoqua Water Technologies Filter V-500-6

Need answers fast?
Explore the manual using AI.

Evoqua Water Technologies Filter V-500-6
Evoqua Water Technologies Filter V-500-6

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Evoqua Water Technologies Filter V-500-6

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Evoqua Water Technologies Filter V-500-6

Evoqua Water Technologies Filter V-500-6

Create an account to install this asset package.

Maintenance Plans for Evoqua Water Technologies Filter Model V-500-6

Integrate maintenance plans directly into your work orders in MaintainX.

6 Monthly Internal Assembly and Pawl Maintenance

Check mark

Pawl Installation

Check mark

Hold the pawl in place with thumb pressure and align the teeth correctly.

Check mark

Rotate the shaft until the pawl is seated properly in the reverser threads.

Check mark

Ensure that o-ring is present in pawl retainer.

Check mark

Install the pawl retainer.

Check mark

Rotate the shaft several times to ensure proper functioning of the pawl.

Check mark

Hydraulic Drive Motor Installation

Check mark

Is the hydraulic drive motor installed to generate COUNTER-CLOCKWISE rotation of the scanner shaft?

Check mark

Hardware Tightening

Run this procedureArrow right

Internal Assembly and Pawl Removal Maintenance

Check mark

Required Tools

Check mark

Ensure all required tools are available

Check mark

Disassembly Process

Check mark

Remove internals from tank as described in the manual

Check mark

Remove rotational governor paddles by unscrewing Phillips screws and 5/16” nut and bolt

Check mark

Remove rotational governor by unscrewing 3/16” Allen screw and sliding it off the shaft

Check mark

Remove dirt collector’s nozzles by removing two 9/64” Allen screws at the bases of the nozzles

Run this procedureArrow right

V-1000/1500/2000 Series Filters Disassembling

Check mark

Preparation

Check mark

Ensure all required tools are available

Check mark

Isolation and Pressure Relief

Check mark

Turn the outlet valve off

Check mark

Turn the inlet valve off

Check mark

Relieve pressure inside of filter body

Check mark

Lid and Screen Removal

Check mark

Remove 5/8” nuts, bolts and washers securing the lid

Check mark

Remove lid and store convex side down

Run this procedureArrow right

V-Series Filter Assembling

Check mark

Gasket and Lubrication Precautions

Check mark

Ensure the floating gasket in the lower bulkhead is placed face up towards the reverser.

Check mark

Confirm no lubrication is applied to the pawl and reverser.

Check mark

Filter Element Installation

Check mark

Check that filter elements fit into the grooves in the differing bulkheads before securing the filter assembly.

Check mark

Ensure screen filters are properly placed into the bulkhead grooves after mounting the rotor assembly.

Check mark

Bulkhead Seal Lubrication

Check mark

Select the lubricant type for bulkhead seals

Check mark

Verify bulkhead seals are lubricated before installing the filter assembly into the tank.

Run this procedureArrow right

Parts for Evoqua Water Technologies Filter V-500-6

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Sensor, Assy 250-2500 Std

1001-1240

Replacement Tank 1000-08-F

1002-2438

Replacement Tank 1000-08-F (1)

1002-2790

Nut, Hex 5/8-11 Zinc Plated

1001-0484

Washer Flat 5/8In Sae 1-5/16 Od Zinc Plt

1001-0476

Sensor, Assy 250-2500 Std

1001-1240

Replacement Tank 1000-08-F

1002-2438

Replacement Tank 1000-08-F (1)

1002-2790

Nut, Hex 5/8-11 Zinc Plated

1001-0484

Washer Flat 5/8In Sae 1-5/16 Od Zinc Plt

1001-0476

Sensor, Assy 250-2500 Std

1001-1240

Replacement Tank 1000-08-F

1002-2438

Replacement Tank 1000-08-F (1)

1002-2790

Nut, Hex 5/8-11 Zinc Plated

1001-0484

Washer Flat 5/8In Sae 1-5/16 Od Zinc Plt

1001-0476

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Evoqua Water Technologies

Explore Other Assets