The Donaldson Cartridge Dust Collector DWS 6-4 is a high-efficiency industrial dust collection system designed to capture airborne particulates. With its robust construction and advanced filtration technology, this model ensures optimal air quality and compliance with environmental regulations, making it ideal for various industrial applications.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Donaldson Cartridge Dust Collector DWS 6-4
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Cartridge Dust Collector Filter Replacement
Filter Removal and Installation
Use proper safety and protective equipment when removing contaminants and filters.
Dirty filters may be heavier than they appear.
Use care when removing filters to avoid personal injury.
Filter Removal
Note: Remove filter cartridges by opening the top and bottom doors. Start with the top filters first. Optional plastic filter bags are offered for filter and dustpan dust removal for cleanliness.
1. Turn the knob counterclockwise until it is loose. Remove the knob and access cover.
2. Remove the filter cartridge from the yoke.
Filter Installation
Cartridge Dust Collector Operational Checklist
Safety Instructions
All personnel instructed on safe use and maintenance procedures?
Electrical service or maintenance work performed by a qualified electrician and comply with all applicable national and local codes?
Power turned off and locked out electrical power sources before performing service or maintenance work?
Compressed air supply turned off and lines bled before performing service or maintenance work?
Compressed-air pressure set below 50 psig to avoid component damage?
All compressed air components sized to meet the maximum system requirements of 60 psig supply pressure?
Compressed-air supply oil and moisture free?
Compressed air lines purged to remove debris before connecting to the unit’s compressed air manifold?
Chamber Silencer and Acoustic Curtain Replacement
Acoustic Curtain for Power Module
1. Install the acoustic curtain to the front of the power module by aligning the acoustic curtain holes with the non-louvre door holes and secure with nylon Christmas Tree clips.
Chamber Silencer
Electrical work must be performed by a qualified electrician and comply with all applicable national and local codes.
Turn power off and lock out electrical power sources before performing service or maintenance work.
Do not install in classified hazardous atmospheres without an enclosure rated for the application.
Install chamber silencer after the motors are wired and rotation checked.
Install the silencer to the top of the power module using the hardware supplied.;
Fluorescent Bulb Replacement
Light Fixture
Electrical work must be performed by a qualified electrician and comply with all applicable national and local codes.
Turn power off and lock out electrical power sources before performing service or maintenance work.
Do not install in classified hazardous atmospheres without an enclosure rated for the application.
- Industrial Light Fixture
This light fixture uses a wrap-around lens that is not fastened to the light housing by fasteners or latches.
To remove the lens: Lift lens one side at a time up and away from the housing.
To replace the bulbs: Rotate and remove from the rotary-lock lamp holders.
Replace with 40-watt, 48-inch long fluorescent bulbs.
IEC Control Panel Inspection
IEC Control Panel with Programmable Logic Control
This control panel contains a safety disconnect switch, blower motor control, pulse control functions, and a Magnehelic gauge. The Programmable Logic Control, PLC, provides features such as sequential start-up, staggered aftershift cleaning, and troubleshooting capabilities.
Blower Control Functions
1. This control panel includes magnetic starters with a low-voltage control circuit.
2. The blower motor ON/OFF buttons are located on the control panel cover. A red blower motor RUNNING light is also provided.
3. Sequential start-up is provided for all DWS 4- and DWS 6-2, 3, and 4 modules. This allows a delay between starting each blower motor and reduces undesirable overload current at start-up.
4. The control panel has troubleshooting capabilities. If a blower motor shuts down due to a failure, such as an overload, the panel will flash the red RUNNING light quickly. The two amber lights, CLEANING and AFTERSHIFT CLEANING, will also flash indicating which circuit tripped the alarm.
For example: The overload on motor protector #3 is tripped. The red RUNNING light will flash quickly and the two amber lights, CLEANING and AFTERSHIFT CLEANING, will flash three times, then pause and repeat. This indicates that motor protector #3 has been tripped. The lights will continue to flash until the alarm is serviced.
5. Thermal overload relays and circuit breakers are provided for the motor circuit and fuses for the low voltage circuit. Standard voltages available are 208/230/460/575/60 Hz/3 phase.
Access the parts list for your equipment in MaintainX.
Cellulex
P199411-016-340
Endura-Tek
P030685-016-340
Endura-Tek FR
P033840-016-340
Endura-Tek XL
P033023-016-340
Fibra-Web
P199413-016-431
Cellulex
P199411-016-340
Endura-Tek
P030685-016-340
Endura-Tek FR
P033840-016-340
Endura-Tek XL
P033023-016-340
Fibra-Web
P199413-016-431
Cellulex
P199411-016-340
Endura-Tek
P030685-016-340
Endura-Tek FR
P033840-016-340
Endura-Tek XL
P033023-016-340
Fibra-Web
P199413-016-431
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX