Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Screw Chiller AWV014
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Screw Chiller Maintenance
Monthly operations include all weekly operations.
General:
- Inspect unit for loose or damaged components and visible leaks
Electrical ( * including the VFDs):
- Visually inspect components for signs of overheating
- Verify compressor and oil heater operation
Refrigeration/Lubricant:
- Leak test
- Check filter-drier pressure drop. Replace the filter if pressure drop exceeds 20 psi.;
1 Weekly Liquid Line Sight Glass Inspection
Warning: This inspection requires trained personnel with PPE!
Is the refrigerant sight glass clear?
If the sight glass is not clear, there might be inadequate refrigerant charge in the system.
Is there bubbling refrigerant in the sight glass during stable run conditions?
Bubbling refrigerant may indicate an EXV problem or excessive pressure drop in the liquid line.
Is the sight glass indicating a dry condition after about 12 hours of operation?
If the sight glass does not indicate a dry condition, an oil acid test is recommended.
Sign off on the sight glass inspection
1 Weekly Screw Chiller Maintenance
General
Complete unit log and review. Log readings can be taken daily for a higher level of unit observation.
Electrical (including the VFDs)
Clean control box fan filter. The weekly fan filter cleaning schedule can be modified to meet job conditions. It is important that the filter allows full air flow.
Refrigeration/Lubricant
Check liquid line sight glasses for clear flow
Check compressor oil sight glass for correct level (lubricant charge);
1 Yearly Screw Chiller Maintenance
Annual (or spring startup) operations include all weekly and monthly operations.
General:
- Inspect thermal insulation for integrity
- Clean and paint as required
Electrical ( * including the VFDs):
- Sequence test controls
- Check contactors for pitting, replace as required
- Check terminals for tightness, tighten as necessary
- Clean control panel interior
3 Monthly Epoxy Coated Coils Cleaning
Warning: This cleaning procedure requires trained personnel with PPE!
Surface debris removed from the coil?
Select the cleaning agent used
Cleaning agent applied uniformly across the substrate?
Substrate thoroughly wetted?
Rinsed off the salts with a hose?
Used potable quality water for rinsing?
Avoided use of harsh chemicals, household bleach or acid cleaners?
Sign off on the coil cleaning
Access the parts list for your equipment in MaintainX.
AWG Wire
83804
AWG Wire Gauge
83754
Chloride Remover, Chlor*Rid Int’l, Inc. P.O. Box 908 Chandler, AZ 85244 800-422-3217
Chlor*Rid DTS
Enviro-Coil Concentrate, Hydro-Balance Corp P.O. Box 730 Prosper, TX 75078 800-527-5166
H-EC01
AWG Wire
83804
AWG Wire Gauge
83754
Chloride Remover, Chlor*Rid Int’l, Inc. P.O. Box 908 Chandler, AZ 85244 800-422-3217
Chlor*Rid DTS
Enviro-Coil Concentrate, Hydro-Balance Corp P.O. Box 730 Prosper, TX 75078 800-527-5166
H-EC01
AWG Wire
83804
AWG Wire Gauge
83754
Chloride Remover, Chlor*Rid Int’l, Inc. P.O. Box 908 Chandler, AZ 85244 800-422-3217
Chlor*Rid DTS
Enviro-Coil Concentrate, Hydro-Balance Corp P.O. Box 730 Prosper, TX 75078 800-527-5166
H-EC01
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX