The Daikin Outdoor Heat Pump 3MXS40K3V1B is a high-efficiency HVAC solution designed for residential and commercial applications. This model offers reliable heating and cooling performance, ensuring optimal comfort while minimizing energy consumption. Ideal for various settings, it combines advanced technology with durable construction for long-lasting operation.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Outdoor Heat Pump 3MXS40K3V1B
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Coil / Thermistor Removal
Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
1 Pull out the electronic expansion valve coils.
2 Remove the screw and remove the four way valve coil.
The cooling only models have no four way valve coil.
3 Open the putty and remove the liquid pipe thermistors.
When reassembling, meet the edge of the thermistor and the fixture.
4 Pull out the gas pipe thermistors.
Be careful not to lose the clip.
The positions of the clamp and outdoor heat exchanger thermistor differ depending on the model.
Compressor Removal
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas brazing machine.
If the refrigerant gas leaks during work, ventilate the room. (If the refrigerant gas is exposed to flames, toxic gas may be generated.)
Since it may happen that the refrigerant oil in the compressor catches fire, prepare wet cloth so as to extinguish fire immediately.
Caution
From the viewpoint of global environment protection, do not discharge the refrigerant gas in the atmosphere. Make sure to collect all the refrigerant gas.
Restore the piping by non-oxidation brazing.
Note
Distributor Removal
Warning:
Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas brazing machine.
If the refrigerant gas leaks during work, ventilate the room. (If the refrigerant gas is exposed to flames, toxic gas may be generated.)
Caution:
From the viewpoint of global environment protection, do not discharge the refrigerant gas in the atmosphere. Make sure to collect all the refrigerant gas.
Restore the piping by non-oxidation brazing.
Note:
Before working, make sure that the refrigerant gas is empty in the circuit.
Electrical Box Removal
Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
1. Disconnect the harnesses.
1 Peel off the fixing tape.
2 Unfasten the 4 hooks and remove the electrical box cover.
3 Detach the clamp and disconnect the connector [S70].
[S70]: fan motor
When reassembling, insert the clamp into either hole as below.
Some models have no ferrite lead wire from the hooks.
4 Release the fan motor core for the harness of [S70].
Fan Motor Removal
Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
1 Remove the 2 screws and remove the fan motor fixing plate.
When reassembling, fit the lower hooks.
2 Remove the nut and remove the outdoor fan.
Nut size: M6
When reassembling, align the mark of the outdoor fan with the D-cut section of the motor shaft.
When reassembling, put the fan motor lead wire through the back of the fan motor so as not to be entangled with the outdoor fan.
3 Open the 2 hooks and release the fan motor lead wire.
4 Remove the 4 screws and remove the fan motor.;
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX