The Daikin Packaged Rooftop System DPS020AHMG2FV4 is a high-efficiency HVAC solution designed for commercial applications. This rooftop unit combines advanced technology with reliable performance, ensuring optimal climate control and energy savings for your facility. Ideal for various environments, it provides effective heating and cooling solutions tailored to your needs.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Packaged Rooftop System DPS020AHMG2FV4
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Filter Replacement
Warning: Ensure the unit is turned off before starting the procedure
Select the cabinet size
Based on the cabinet size, use the appropriate filter size
Filter replaced successfully?
Sign off on the filter replacement
Rooftop System Charge Maintenance
Re-charge the unit
The Rebel unit has many configurable options that can affect the refrigerant charge. Actual unit charge is given on the unit's data plate found on the inside of the control panel
The Rebel unit uses electronic expansion valves that maintain peak efficiency. Liquid sub-cooling and suction super heat float and should not be used as an indication that charge needs to be added or removed from the system
If a leak is suspected, the full charge should be removed and weighed. Weight should be compared against the unit nameplate data. Unit should be recharged with the amount given on the unit nameplate
POE and PVE oil is hygroscopic and does absorb moisture when exposed to atmosphere. Steps should be taken to minimize exposure time to atmosphere during any maintenance where the sealed system is to be opened
Rebel 003-015 refrigerant systems use only Polyvinylether (PVE) oil. Rebel 016-028 refrigerant systems use only Polyester (POE) oil
NOTICE: Do not use POE oil in DPS 003-015 refrigerant systems and do not use PVE oil in DPS 016-028 refrigerant systems
The entire system must be evacuated using a suitable vacuum pump
The quality of vacuum is measured using a suitable micron gauge that has been calibrated
6 Monthly Rooftop System Maintenance
Check combustion inducer fan for dirt buildup and lint
Check combustion air intake louvers and flue box/vent for accumulation of dirt and debris
Inspect and clean flue tubes and combustion chamber
Keep burner vestibule clean. Dirt and debris can result in poor combustion and lower efficiency
Sign off on the rooftop system maintenance
3 Monthly Coated Coil Cleaning
Clean Option E Coated Coils Surfaces
Quarterly cleaning is essential to extend the life of an Option E Coated Coil and is required to maintain warranty coverage
Coil cleaning shall be part of the unit's regularly scheduled maintenance procedures
Failure to clean an Option E Coated Coil will void the warranty and may result in reduced efficiency and durability in the environment
For routine quarterly cleaning, first clean the coil with the below approved coil cleaner
Coil cleaned with approved cleaner?
After cleaning the coils with the approved cleaning agent, use the approved chloride remover (under the Recommended Chloride Remover section) to remove soluble salts and revitalize the unit
Coil cleaned with approved chloride remover?
Sign off on the coil cleaning
Compressor Ground Fault Interrupter Service
Warning: This service requires trained personnel with PPE!
Rebel 003–015 units equipped with a ground fault interrupter?
Current sensing donut on the power wires to the compressor(s) present?
PCB present?
The device is intended for personal safety by continuously monitoring the balance between the three phase power and the neutral conductor.
It is not intended to provide overcurrent or short circuit protection to the equipment.
The device works by opening the 120V controls circuit in a fault condition?
An open condition on the ground fault interrupter indicates the compressor has been grounded?
Sign off on the Compressor Ground Fault Interrupter Service
Access the parts list for your equipment in MaintainX.
Modulating Furnace
404225353
LP Gas Furnace
404231245
Natural Gas Furnace
404231254
Modulating Furnace
404225356
Natural Gas Furnace
404231252
Modulating Furnace
404225353
LP Gas Furnace
404231245
Natural Gas Furnace
404231254
Modulating Furnace
404225356
Natural Gas Furnace
404231252
Modulating Furnace
404225353
LP Gas Furnace
404231245
Natural Gas Furnace
404231254
Modulating Furnace
404225356
Natural Gas Furnace
404231252
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX