Daikin Packaged Rooftop System DPS020AHMG2FV4
Daikin Packaged Rooftop System DPS020AHMG2FV4

The Daikin Packaged Rooftop System DPS020AHMG2FV4 is a high-efficiency HVAC solution designed for commercial applications. This rooftop unit combines advanced technology with reliable performance, ensuring optimal climate control and energy savings for your facility. Ideal for various environments, it provides effective heating and cooling solutions tailored to your needs.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Packaged Rooftop System DPS020AHMG2FV4

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Packaged Rooftop System DPS020AHMG2FV4

Daikin Packaged Rooftop System DPS020AHMG2FV4

Create an account to install this asset package.

Maintenance Plans for Daikin Packaged Rooftop System Model DPS020AHMG2FV4

Integrate maintenance plans directly into your work orders in MaintainX.

Filter Replacement

Check mark

Warning: Ensure the unit is turned off before starting the procedure

Check mark

Select the cabinet size

Check mark

Based on the cabinet size, use the appropriate filter size

Check mark

Filter replaced successfully?

Check mark

Sign off on the filter replacement

Run this procedureArrow right

Rooftop System Charge Maintenance

Check mark

Re-charge the unit

Check mark

The Rebel unit has many configurable options that can affect the refrigerant charge. Actual unit charge is given on the unit's data plate found on the inside of the control panel

Check mark

The Rebel unit uses electronic expansion valves that maintain peak efficiency. Liquid sub-cooling and suction super heat float and should not be used as an indication that charge needs to be added or removed from the system

Check mark

If a leak is suspected, the full charge should be removed and weighed. Weight should be compared against the unit nameplate data. Unit should be recharged with the amount given on the unit nameplate

Check mark

POE and PVE oil is hygroscopic and does absorb moisture when exposed to atmosphere. Steps should be taken to minimize exposure time to atmosphere during any maintenance where the sealed system is to be opened

Check mark

Rebel 003-015 refrigerant systems use only Polyvinylether (PVE) oil. Rebel 016-028 refrigerant systems use only Polyester (POE) oil

Check mark

NOTICE: Do not use POE oil in DPS 003-015 refrigerant systems and do not use PVE oil in DPS 016-028 refrigerant systems

Check mark

The entire system must be evacuated using a suitable vacuum pump

Check mark

The quality of vacuum is measured using a suitable micron gauge that has been calibrated

Run this procedureArrow right

6 Monthly Rooftop System Maintenance

Check mark

Check combustion inducer fan for dirt buildup and lint

Check mark

Check combustion air intake louvers and flue box/vent for accumulation of dirt and debris

Check mark

Inspect and clean flue tubes and combustion chamber

Check mark

Keep burner vestibule clean. Dirt and debris can result in poor combustion and lower efficiency

Check mark

Sign off on the rooftop system maintenance

Run this procedureArrow right

3 Monthly Coated Coil Cleaning

Check mark

Clean Option E Coated Coils Surfaces

Check mark

Quarterly cleaning is essential to extend the life of an Option E Coated Coil and is required to maintain warranty coverage

Check mark

Coil cleaning shall be part of the unit's regularly scheduled maintenance procedures

Check mark

Failure to clean an Option E Coated Coil will void the warranty and may result in reduced efficiency and durability in the environment

Check mark

For routine quarterly cleaning, first clean the coil with the below approved coil cleaner

Check mark

Coil cleaned with approved cleaner?

Check mark

After cleaning the coils with the approved cleaning agent, use the approved chloride remover (under the Recommended Chloride Remover section) to remove soluble salts and revitalize the unit

Check mark

Coil cleaned with approved chloride remover?

Check mark

Sign off on the coil cleaning

Run this procedureArrow right

Compressor Ground Fault Interrupter Service

Check mark

Warning: This service requires trained personnel with PPE!

Check mark

Rebel 003–015 units equipped with a ground fault interrupter?

Check mark

Current sensing donut on the power wires to the compressor(s) present?

Check mark

PCB present?

Check mark

The device is intended for personal safety by continuously monitoring the balance between the three phase power and the neutral conductor.

Check mark

It is not intended to provide overcurrent or short circuit protection to the equipment.

Check mark

The device works by opening the 120V controls circuit in a fault condition?

Check mark

An open condition on the ground fault interrupter indicates the compressor has been grounded?

Check mark

Sign off on the Compressor Ground Fault Interrupter Service

Run this procedureArrow right

Parts for Daikin Packaged Rooftop System DPS020AHMG2FV4

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Modulating Furnace

404225353

LP Gas Furnace

404231245

Natural Gas Furnace

404231254

Modulating Furnace

404225356

Natural Gas Furnace

404231252

Modulating Furnace

404225353

LP Gas Furnace

404231245

Natural Gas Furnace

404231254

Modulating Furnace

404225356

Natural Gas Furnace

404231252

Modulating Furnace

404225353

LP Gas Furnace

404231245

Natural Gas Furnace

404231254

Modulating Furnace

404225356

Natural Gas Furnace

404231252

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets