The Daikin Air Handler CAH011GDAM is a high-efficiency air handling unit designed for optimal indoor climate control. This model features advanced technology for reliable performance and energy savings, making it ideal for commercial and industrial applications. Enhance your HVAC system with this robust air handler from Daikin.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Air Handler CAH011GDAM
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Bub Replacement
WARNING: Personal Injury Hazard. Power supply can cause electrical shock. Always disconnect all power to unit before servicing
WARNING: UV-C exposure is harmful to the skin and eyes. Looking at an illuminated UV-C bulb can cause permanent blindness. UV-C skin exposure can cause cancer
WARNING: Fluorescent bulbs contain mercury, which can cause personal injury if breathed or ingested. Use appropriate protective gear to clean up broken bulbs
Verify the UV lights are off by using the view window
Disconnect power to the power receptacle before servicing
Verify the power is disconnected
Before opening the access panels, use the viewing window to make sure the UV lights are off
Before handling, allow bulbs to cool for 5 minutes
Grasp body of bulb firmly at each end
LVP Variable Speed Sheave Maintenance
Warning: This maintenance check requires trained personnel with PPE!
Belt tension slacked off if belts have been installed?
Setscrews D loosened?
Capscrews E loosened but not removed?
Key F removed?
Pitch diameter adjusted by opening or closing the movable flanges by half or full turns?
Note: Two-groove sheaves are supplied with both grooves set at the same pitch diameter. To provide the same pitch diameter for satisfactory operation, move both movable flanges the same number of turns. Do not open sheaves more than five turns for A belts or six turns for B belts.
Key F replaced?
Setscrews D and capscrews E tightened?
6 Monthly Coil Maintenance
Warning: This maintenance check requires trained personnel with PPE!
Drain pans in any air conditioning unit may have some moisture.
Algae, etc., can grow due to airborne spores and bacteria.
Periodic cleaning is necessary to prevent this buildup from plugging the drain and causing the drain pan to overflow.
Also, keep the drain pans clean to prevent the spread of disease.
Cleaning should be performed by qualified personnel.
Dirt and lint can clog the condensate drain, especially with dirty filters. Inspect twice a year to help avoid overflow.
Sign off on the coil maintenance
Coil Maintenance
Winterize Water Coils
Coils cleaned and free from mold?
Coils drained thoroughly?
Freezing point of antifreeze solution
Remove and Replace Components of Coils
Power to the unit locked out and tagged out?
Flat head fasteners removed from the panel?
Frame channels removed?
Fan section removed?
Pitch Key Sheave Maintenance
Loosen setscrews B and C in moving parts of sheave and pull out external key E
Adjust sheave pitch diameter for desired speed
Replace external key E and securely tighten setscrews B over key and setscrews C into keyway in fixed half of the sheave
Put on belts and adjust tension
Make future adjustments by loosening the belt tension and increasing or decreasing the pitch diameter of the sheave as required
Adjust both halves of the two-groove sheaves by the same number of turns from closed position
Verify that all keys are in place and that all se screws are tight before starting drive
Check setscrews and belt tension after 24 hours service
Sign off on the Pitch Key Sheave Maintenance
Access the parts list for your equipment in MaintainX.
Replacement Bulb
205484001
Replacement Bulb
205484201
Replacement Bulb
205484101
Replacement Bulb
205484001
Replacement Bulb
205484201
Replacement Bulb
205484101
Replacement Bulb
205484001
Replacement Bulb
205484201
Replacement Bulb
205484101
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX