The Daikin Air Conditioner FTXS95LVMA/RXS95LVMA is a high-efficiency cooling solution designed for residential and commercial applications. Known for its reliability and advanced features, this model ensures optimal comfort and energy savings, making it a preferred choice for climate control.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Air Conditioner FTXS95LVMA/RXS95LVMA
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Air Conditioner Check
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation
If no drain water is seen, is water leaking from the indoor unit?
Before a long idle period
Operate the FAN only for several hours on a nice day to dry out the inside
After operation stops, turn off the breaker for the room air conditioner
Clean the air filters and set them again
Take out batteries from the remote controller
Air Conditioner Cleaning
CAUTION: Before cleaning, be sure to stop the operation and turn off the circuit breaker
Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury
Is the circuit breaker turned off?
Is the operation stopped?
Clean Indoor unit
Clean Outdoor unit
Clean Remote controller
For cleaning, do not use the materials as follows: Hot water above 40°C, Benzine, gasoline, thinner, other volatile oils, Polishing compound, Scrubbing brushes, other hard stuff
Sign off on the air conditioner cleaning
6 Monthly Air-Purifying Filter Maintenance
Warning: The method of cleaning and replacement of the filters may differ depending on the model. Refer to the label attached to the separately sold filters themselves.
Take off the titanium apatite photocatalytic air-purifying filter
Clean or replace the titanium apatite photocatalytic air-purifying filter
If dirt is heavy, soak in lukewarm water or water for about 10 to 15 minutes
After washing, shake off remaining water and dry in the shade
Do not wring out the filter when removing water from it
Remove the tabs on the filter frame and replace with a new filter
Do not throw away the filter frame. Reuse the filter frame when replacing the titanium apatite photocatalytic air-purifying filter
Dispose of the old filter as non-flammable waste
2 Weekly Air Filter Cleaning
Warning: Do not touch the aluminum fins by bare hand at the time of dismounting or mounting the filter
Air Conditioner Air Filter cleaned
Dust vacuumed or filter washed
Air filters pulled out
Air filters washed with water or cleaned with vacuum cleaner
If dust does not come off easily, air filters washed with neutral detergent thinned with lukewarm water
Titanium apatite photocatalytic air-purifying filter removed
Filters set as they were and front panel closed
Sign off on the air filter cleaning
Front Panel Cleaning
CAUTION: When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully
CAUTION: When removing or attaching the front panel, support the panel securely with hand to prevent it from falling
CAUTION: After cleaning, make sure that the front panel is securely fixed
Is the front panel bothered by dirt?
If the front panel is dirty, proceed with the following steps
Remove the front panel
Was the front panel removed successfully?
Clean the front panel
Was the front panel cleaned successfully?
Access the parts list for your equipment in MaintainX.
Air-Purifying Filter
KAF970A48
Dry Batteries
AAA.LR03
Remote Controller
ARC452A4
Air-Purifying Filter
KAF970A48
Dry Batteries
AAA.LR03
Remote Controller
ARC452A4
Air-Purifying Filter
KAF970A48
Dry Batteries
AAA.LR03
Remote Controller
ARC452A4
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX