MaintainX Asset Hub logo
EnterprisePricing
Case

Case Loader Backhoe 580BCK

Need answers fast?
Explore the manual using AI.

Case Loader Backhoe 580BCK
Case Loader Backhoe 580BCK

The Case Loader Backhoe 580BCK is a versatile and powerful piece of industrial equipment designed for construction and excavation tasks. Known for its reliability and efficiency, this backhoe loader is ideal for various applications, ensuring optimal performance and productivity on the job site.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Case Loader Backhoe 580BCK

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Case Loader Backhoe 580BCK

Case Loader Backhoe 580BCK

Create an account to install this asset package.

Maintenance Plans for Case Loader Backhoe Model 580BCK

Integrate maintenance plans directly into your work orders in MaintainX.

10 Hourly Backhoe Lubrication

Check mark

Warning: This lubrication procedure requires trained personnel with PPE!

Check mark

If the backhoe is used in severe or abnormal working conditions, reduce the time interval by one half.

Check mark

Remove dirt from grease fittings before applying grease gun.

Check mark

Stabilizer cylinder lubricated?

Check mark

Swing cylinder trunnion (early production) lubricated?

Check mark

Swing cylinder trunnion (late production) lubricated?

Check mark

Swing cylinder rod eye lubricated?

Check mark

Swing tower pivots lubricated?

Check mark

Boom pivots lubricated?

Run this procedureArrow right

10 Hourly Loader Lubrication

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Loader frame pivot lubricated

Check mark

Hydra-Leveling cylinder lubricated

Check mark

Lift cylinder (early production) lubricated

Check mark

Lift cylinder (late production) lubricated

Check mark

Tilt cylinder lubricated

Check mark

Tilt cylinder trunnion lubricated

Check mark

Bucket link lubricated

Check mark

Bucket pivot (early production only) lubricated

Run this procedureArrow right

10 Hourly Three-Point Hitch Lubrication

Check mark

Warning: Ensure the hitch is not in use and is in a safe state before starting the procedure

Check mark

Lift cylinder lubricated

Check mark

Lift arm lubricated

Check mark

Tilt cylinder rod eye lubricated

Check mark

Sign off on the lubrication procedure

Run this procedureArrow right

500 Hourly / 2 Yearly ROPS Maintenance

Check mark

Check torque on ROPS mounting bolts and retorque to specifications if required.

Check mark

Upload a photo of the ROPS mounting bolts after retorquing

Check mark

Inspect the operator's seat and seat belt mounting.

Check mark

Upload a photo of the operator's seat and seat belt mounting after inspection

Check mark

Any damaged or worn parts found during inspection?

Check mark

List the damaged or worn parts found

Check mark

Sign off on the ROPS maintenance

Run this procedureArrow right

500 Hourly Hydraulic Oil Change

Check mark

Park the machine on a level surface.

Check mark

Have the backhoe in the transport position, if so equipped, and the loader bucket rolled back at ground level.

Check mark

Remove the drain plug from the elbow at the bottom of each subframe. Approximately 5-1/2 U.S. gallons will drain from each subframe.

Check mark

Remove the reservoir breathers and clean as instructed.

Check mark

Replace the hydraulic oil filter as instructed.

Check mark

Reinstall the drain plugs.

Check mark

NOTE: Due to production changes, the breathers and plugs may be located on the opposite side from the side shown.

Check mark

Remove the vent plug from the front of the subframe.

Check mark

Fill the reservoir through the large breather opening until oil appears at the vent plug opening, then reinstall the plug.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Case

Explore Other Assets