The Bunn Liquid Coffee Ambient Dispenser LCA-2PC is a reliable and efficient solution for serving ambient coffee. Designed for commercial use, this dispenser ensures consistent quality and temperature control, making it ideal for cafes and restaurants. Regular maintenance is essential for optimal performance and longevity.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Bunn Liquid Coffee Ambient Dispenser LCA-2PC
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Dispenser Maintenance
Rinse the dispenser
Open the dispenser door
Select Rinse on the Function Selector Switch and Run on the Mode Selector Switch
Close the dispenser door
Place a 1/2 gal (2 liter) container under the appropriate dispense nozzle or nozzles
Activate the Dispenser of the appropriate side or sides for approximately twenty seconds or until the hot water is clear or has no concentrate coloring in it
Open the dispenser door, select Normal on the Function Selector Switch, and then close door
Note: To clear the 'Rinse' alarm, activate each dispenser until the flow stops automatically (approx. 20 seconds for each tip). The 'Rinse' alarm LED will turn off when the Rinse Procedure has been satisfied for both sides
Wash the dispenser
1 Weekly Dispenser Maintenance
Open the dispenser door
Select Prime on the Function Selector Switch and Run on the Mode Selector Switch
Remove the bag connector from the product box and disassemble or prop open the internal valve to allow free flow of product through the connector
Place the bag connector into a one-gallon (3.8 liter) container of warm soapy tap water 140°F (60°C)
Place an empty container under dispense tip and activate the corresponding Dispenser until the clean soapy water is dispensed from the dispense tip
Repeat steps 4 and 5 with warm tap water 140°F (60°C) to rinse the soapy water from the pump tubing
Continue dispensing until the water is clear, and no soapy water is being dispensed
Prepare 2.5 gallons (9.46L) of sanitizing solution by dissolving 1 packet of Kay 5 sanitizer into 2.5 gallons (9.46L) of 120°F (48.9°C) water to ensure 100 ppm of available chlorine
Again, repeat steps 4 and 5 with the sanitizing solution. Once sanitizing solution is visible, continue to dispense for 1 minute. Release handle and allow solution to sit for 5 minutes
6 Monthly Dispenser Pump Tubing Replacement
NOTE: Replacement parts or service caused by failure to perform required maintenance is not covered by warranty
Replace pump hoses every 6-Months or as needed
The pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a wear item and must be replaced periodically.
Rinse the pump tubing with warm tap water
Loosen the thumbscrew securing the tubing retainer plate to the pump housing
Depress the tension screw and remove it from the notch in the pump housing, releasing the spring tension on the pump band
Open the compression band and gently pull the pump tube from around the pump's rotor
Inspect the pump bands for signs of wear. Replace if necessary
Apply lubricant (BUNN-O-MATIC part number M2531.0001) to the new pump tubing's rotor side.
Dispenser Concentrate Pump/Flow Rates Calibration
Remove the lower splash guard assembly to access prior to starting this procedure
NOTE: You can calibrate either the Concentrate Pump or the Dispenser Flow Rate independently. Simply scroll through the menu screen to the desired section and perform only those steps
Select PRIME on the Function Selector Switch. (refer to Priming the Concentrate Lines)
Place a container under the Left Dispense Tip and prime the concentrate lines until a steady stream of concentrate comes out the tip (approximately 10 seconds)
Stop the Priming and allow the tip to stop dripping. Discard the concentrate collected
Select NORMAL on the Function Selector Switch
Locate the programming module and use the Arrow Down key to scroll through LCD screens until CAL LEFT SIDE appears and press the YES button
The CAL LEFT PUMP menu screen will be displayed. Place a 50 ml graduated cylinder under Left Dispense Tip and activate the Left Dispenser momentarily. The dispenser will run the Left Concentrate Pump for 20 seconds and then shut OFF automatically
Measure the volume of concentrate collected in the graduated cylinder
Dispenser Empty BIB Threshold Calibration
Remove the lower splash guard assembly to access the digital programming module with LCD display
Open the cabinet door and set the Function Switch to the Rinse position. Close the door
Place a large container under the Left dispenser tip, then activate and hold the left dispenser
Dispense long enough to rinse all the concentrate out of the mix chamber and for the Conductance reading to stabilize and stop dropping
Record the nominal Conductance value displayed. This is the conductance reading of the water in your area
Repeat steps 3, 4 & 5 for the Right dispenser
Add 100 points to the larger of the Left or Right side Conductance value. This is the new Empty BIB threshold value for your dispenser
Enter this new value into the Empty BIB Alarm threshold
Sign off on the calibration
Access the parts list for your equipment in MaintainX.
Lubricant
M2531.0001
Tube Kit
34727.1000
Tube Kit
34728.1000
Lubricant
M2531.0001
Tube Kit
34727.1000
Tube Kit
34728.1000
Lubricant
M2531.0001
Tube Kit
34727.1000
Tube Kit
34728.1000
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX