The Atlas Copco Stationary Air Compressor GR132W is a robust and efficient air compressor designed for industrial applications. With its advanced technology and reliable performance, this model ensures optimal air supply and energy efficiency, making it an essential asset for any manufacturing environment.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Atlas Copco Stationary Air Compressor GR132W
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Display Check
Warning: Before carrying out any maintenance, repair or adjustment, stop the compressor, press emergency stop button and switch off the voltage. Close the air outlet valve and open the manual condensate drain valve(s)
Check the display for readings and messages
Check if alarm LED (3) is alight or blinks
Check if the display shows a service message
Check if the component needs to be replaced, oil changed or drive motor greased
Check if the relevant timer needs to be reset
Check the actual compressor condition including the temperatures and pressures, the status of controlling the compressor (automatic or manual, local or remote) and the status of the compressor start/stop timer (active or not active)
Check that condensate is discharged during loading every 1 Day
Sign off on the daily display check
2000 Hourly / 1 Yearly HD Roto-Inject Fluid Oil Change
Run the compressor until warm
Stop the compressor and switch off the voltage
Depressurize by unscrewing plug only one turn to permit any pressure in the system to escape
Loosen vent plugs on top of the coolers (GR)
Drain the oil by removing the drain plugs
Tighten the plugs after draining
Remove filler plug
Fill the air receiver with oil until the level reaches the filler opening
Reinstall and tighten plug
3 Monthly Stationary Air Compressor Maintenance
Operate the safety valve by unscrewing the cap one or two turns and retightening it
Remove, dismantle and clean float valve of condensate trap(s)
Clean compressor
Check for possible leaks
Sign off on the compressor maintenance
4000 Hourly / 1 Yearly Air Filter Change
Compressor stopped and voltage switched off
Filters removed
New filters fitted
Air filter service warning reset using key <<Reset>> in submenu <<Service>>
Sign off on the air filter change
4000 Hourly / 1 Yearly Oil Filter Change
Safety Warning: Ensure the compressor is stopped, voltage is switched off and the system is depressurized before starting the procedure.
Depressurized the system by unscrewing plug only one turn?
Provided an oil pan to avoid possible oil spilling?
Removed oil filters?
Cleaned the filter seats on the manifold?
Oiled the gaskets of the new filters and screwed them into place until the gaskets contact their seats, then tightened by hand?
Tightened filler plug?
Reset the oil filter service warning using key <<Reset>> in submenu <<Service>>?
Sign off on the oil filter change
Access the parts list for your equipment in MaintainX.
HD Roto-Inject Fluid 209L Drum
2901 0572 02
HD Roto-Inject Fluid 20L Can
2901 0572 01
HD Roto-Inject Fluid 209L Drum
2901 0572 02
HD Roto-Inject Fluid 20L Can
2901 0572 01
HD Roto-Inject Fluid 209L Drum
2901 0572 02
HD Roto-Inject Fluid 20L Can
2901 0572 01
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX