The Atlas Copco Oil-Injected Rotary Screw Compressor GA 18 is a reliable and efficient solution for compressed air needs in industrial applications. Known for its durability and performance, this model offers advanced technology to ensure optimal operation and reduced maintenance costs.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Atlas Copco Oil-Injected Rotary Screw Compressor GA 18
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Oil-Injected Rotary Screw Compressor Check
Check oil level
Check readings on display
Check that condensate is discharged during loading
Drain condensate
Check the service indicator on the DD and PD filters (if provided)
1 Yearly Oil-Injected Rotary Screw Compressor Maintenance
Replace DD and PD filters or whenever the pressure indicator points red (if provided)
Inspect the air receiver
Minimum wall thickness as specified in the instruction book must be respected
Local regulations remain applicable if they are more strict
Sign off on the compressor maintenance
3 Monthly Oil-Injected Rotary Screw Compressor Maintenance
Check coolers, clean if necessary
Remove the air filter element. Clean using an air jet and inspect. Replace damaged or heavily contaminated elements
Check the filter element of the electric cabinet (where applicable). Replace if necessary
On Full-Feature units: Check condenser of dryer and clean if necessary. Check and clean the filter
4000 Hourly / 1 Yearly Air Filter Element Replacement
Warning: Ensure the compressor is switched off and the voltage is disconnected before starting the procedure.
Compressor stopped and voltage switched off?
Upload a photo of the side panel before removal
Side panel removed?
Upload a photo of the air filter cover before removal
Air filter cover removed by turning it anti-clockwise?
Upload a photo of the removed filter element
Filter element removed?
Cover cleaned if necessary?
4000 Hourly / 1 Yearly Coolers Cleaning
CAUTION! Never use a high pressure water jet to clean the compressor
Stop the compressor, close the air outlet valve and switch off the voltage
Cover all parts under the coolers
Remove any dirt from the coolers with a fibre brush. Never use a wire brush or metal objects
Next, clean with an air jet in the reverse direction to normal flow. Use low pressure air. If necessary, the pressure may be increased up to 6 bar(e) (87 psig)
Is it necessary to wash the coolers with a cleaning agent?
If it is necessary to wash the coolers with a cleaning agent, consult Atlas Copco
Sign off on the coolers cleaning
Access the parts list for your equipment in MaintainX.
Air Receiver 1400 kPa
2206 1005 03
Air Receiver 16 bar
2204 1005 01
Air Receiver 200 psi
2205 1005 02
Oil Separator Vessel 15 bar
1625 4815 01
Safety Valve IV
6211 1115 69
Air Receiver 1400 kPa
2206 1005 03
Air Receiver 16 bar
2204 1005 01
Air Receiver 200 psi
2205 1005 02
Oil Separator Vessel 15 bar
1625 4815 01
Safety Valve IV
6211 1115 69
Air Receiver 1400 kPa
2206 1005 03
Air Receiver 16 bar
2204 1005 01
Air Receiver 200 psi
2205 1005 02
Oil Separator Vessel 15 bar
1625 4815 01
Safety Valve IV
6211 1115 69
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX