MaintainX Asset Hub logo
EnterprisePricing
A.O. Smith

A.O. Smith Water Heater AT-H3J-DV-N

Need answers fast?
Explore the manual using AI.

A.O. Smith Water Heater AT-H3J-DV-N
A.O. Smith Water Heater AT-H3J-DV-N

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for A.O. Smith Water Heater AT-H3J-DV-N

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

A.O. Smith Water Heater AT-H3J-DV-N

A.O. Smith Water Heater AT-H3J-DV-N

Create an account to install this asset package.

Maintenance Plans for A.O. Smith Water Heater Model AT-H3J-DV-N

Integrate maintenance plans directly into your work orders in MaintainX.

Inlet Gas Pressure Check

Check mark

Safety Precautions

Check mark

Turn off all electric power to the water heater

Check mark

Turn the manual gas valve located on the outside of the unit to the off position

Check mark

Ensure all safety warnings are acknowledged

Check mark

Initial Setup

Check mark

Shut off the manual gas valve on the gas supply line

Check mark

Remove the screw from the pressure port on the gas inlet of the water heater

Check mark

Connect the manometer to the pressure port and zero the manometer

Check mark

Pressure Measurement

Run this procedureArrow right

Inlet Water Filter Cleaning

Check mark

Preparation

Check mark

Close the manual gas shutoff valve

Check mark

Turn off power to the unit and wait a couple of seconds. Turn on again.

Check mark

Wait 30 seconds, and then turn off power to the unit.

Check mark

Isolation

Check mark

Close the inlet water valve

Check mark

Is the heater part of an Easy-Link or Multi-Unit System?

Check mark

If yes, close the inlet and outlet water valves to isolate the heater.

Check mark

Draining Water

Run this procedureArrow right

1 Yearly Water Heater Maintenance

Check mark

Venting System Inspection

Check mark

Check the venting system for leaks

Check mark

Inspect the venting system for corrosion

Check mark

Check the venting system for blockages

Check mark

Inspect the venting system for any damage

Check mark

Burner Inspection

Check mark

Check the burner for dust

Check mark

Inspect the burner for lint

Check mark

Check the burner for grease

Run this procedureArrow right

Water Heater Drain

Check mark

Preparation

Check mark

Close the manual gas shutoff valve

Check mark

Turn off power to the unit and wait a couple of seconds. Turn on again.

Check mark

Wait 30 seconds, and then turn off power to the unit.

Check mark

Water Valve Management

Check mark

Close the inlet water valve. If the heater is part of an Easy-Link or Multi-Unit System, close the inlet and outlet water valves to isolate the heater.

Check mark

Draining Process

Check mark

Open all hot water taps in the house.

Check mark

When the residual water flow has ceased, close all hot water taps.

Run this procedureArrow right

Pressure Relief Valve Maintenance

Check mark

Pre-Operation Check

Check mark

Ensure the discharge area is secure for disposal

Check mark

Valve Operation

Check mark

Manually operate the pressure relief valve to check for correct operation

Check mark

Post-Operation Observation

Check mark

Did the relief valve discharge during normal operation?

Check mark

If yes, describe the issue and note that it may be due to thermal expansion in a closed water supply system. Contact a service technician to correct this issue.

Run this procedureArrow right

Parts for A.O. Smith Water Heater AT-H3J-DV-N

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Front Cover Indoor

100074663

Intake Air Port Assembly

100074667

Junction Box

100074668

Power Supply Cord Assembly

100074669

Condensate Drain Port

100074203

Front Cover Indoor

100074663

Intake Air Port Assembly

100074667

Junction Box

100074668

Power Supply Cord Assembly

100074669

Condensate Drain Port

100074203

Front Cover Indoor

100074663

Intake Air Port Assembly

100074667

Junction Box

100074668

Power Supply Cord Assembly

100074669

Condensate Drain Port

100074203

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from A.O. Smith

Explore Other Assets