MaintainX Asset Hub logo
EnterprisePricing
Ansul

Ansul Fire Extinguisher 20-ABC-SP

Need answers fast?
Explore the manual using AI.

Ansul Fire Extinguisher 20-ABC-SP
Ansul Fire Extinguisher 20-ABC-SP

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Ansul Fire Extinguisher 20-ABC-SP

Ansul Fire Extinguisher 20-ABC-SP

Create an account to install this asset package.

Maintenance Plans for Ansul Fire Extinguisher Model 20-ABC-SP

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Bracket Inspection

Check mark

Check for looseness between extinguisher and bracket. The band clamp should shut tightly, compressing the band grommet.

Check mark

Inspect the extinguisher and the bracket for wear caused by movement of the extinguisher within the bracket.

Check mark

Examine entire bracket closely for loose or worn hinges or hinge-pins, bent or cracked bands, and worn or missing grommets.

Check mark

Clean any pads that are oily or greasy.

Check mark

Did you replace or repair all components that are missing, worn or damaged?

Check mark

Sign off on the bracket inspection

Run this procedureArrow right

1 Yearly Bracket Maintenance

Check mark

Clean any dirt, ice, or other foreign material from the extinguisher and bracket

Check mark

Remove the extinguisher from the bracket and clean the extinguisher surface where the bracket pads contact it

Check mark

Examine the bracket pads which hold the extinguisher in place. Clean the pad surfaces to maintain their gripping power on the extinguisher. Check the pads for resiliency, and replace if necessary

Check mark

Inspect the bracket. If it has been bent, replace it. If it has been cracked, repair or replace it

Check mark

If any welding is performed, take steps to protect the bracket pads from excessive heat

Check mark

Grease each moving part of the bracket arm and test its action. The bracket must be able to hold the extinguisher firmly, but release easily when necessary

Check mark

Check to see that the bracket is firmly mounted. Tighten or replace mounting fasteners, or re-weld connections as needed

Check mark

Avoid possible rust damage by cleaning and painting wherever bare steel is exposed

Check mark

Following extinguisher maintenance, secure the extinguisher in its bracket. If the bracket does not hold the extinguisher securely or the bracket is difficult to close, replace the affected part and/or bracket

Run this procedureArrow right

1 Yearly Fire Extinguisher Maintenance

Check mark

NOTICE: Always be alert for any indications of damage or in-operability in the unit.

Check mark

Extinguisher is in its designated place, conspicuous, readily accessible and immediately available in the event of fire.

Check mark

Extinguisher removed from its wall hanger or bracket. Check the securement of the hanger or bracket.

Check mark

NOTICE: Extinguishers out of service for maintenance or recharge shall be replaced by spare extinguishers of the same type and at least equal rating.

Check mark

Check the date of manufacture stamped on the shell or the date of last hydrostatic test on the label affixed to the extinguisher.

Check mark

Invert the extinguisher and open the nozzle to ensure that any pressure is relieved from the shell.

Check mark

Return extinguisher to the upright position, place the hose in its normal position and insert the nozzle in the holder.

Check mark

Examine the dry chemical shell and all other external components for evidence of corrosion, mechanical damage, or the presence of welding, soldering or brazing repairs.

Check mark

Check the nameplates for legibility, looseness or corrosion.

Run this procedureArrow right

Bracket Adjustment

Check mark

Warning: Improper adjustment may cause damage to the bracket or extinguisher.

Check mark

Extinguisher is firmly in the bracket base

Check mark

Clamp arm is level and arranged for best fit

Check mark

Handle is opened to the correct width

Check mark

T-bolt length is adjusted to fit into the handle notches

Check mark

T-bolt is properly seated and square to the bracket back

Check mark

Handle is carefully closed, clamping the extinguisher into the bracket

Check mark

Bracket adjustment is checked for any play or tension issues

Check mark

Sign off on the bracket adjustment

Run this procedureArrow right

Cartridge Receiver Puncture Pin Replacement

Check mark

Cartridge removed from extinguisher

Check mark

Retaining roll pin removed from lever

Check mark

Old puncture pin removed by pushing downward

Check mark

New puncture pin installed

Check mark

Roll pin installed in reverse procedure

Check mark

Puncture pin travels freely by operating the lever

Run this procedureArrow right

Parts for Ansul Fire Extinguisher 20-ABC-SP

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

12.0 Oz Spray Can – Primer

79729

3M #10 Contact Adhesive

59348

9.0 Oz Spray Can – Red Enamel

79730

9.0 Oz Spray Can – Red Epoxy-CR

79731

Agent Funnels

699

12.0 Oz Spray Can – Primer

79729

3M #10 Contact Adhesive

59348

9.0 Oz Spray Can – Red Enamel

79730

9.0 Oz Spray Can – Red Epoxy-CR

79731

Agent Funnels

699

12.0 Oz Spray Can – Primer

79729

3M #10 Contact Adhesive

59348

9.0 Oz Spray Can – Red Enamel

79730

9.0 Oz Spray Can – Red Epoxy-CR

79731

Agent Funnels

699

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Ansul

Explore Other Assets