Ansul Fire Extinguisher 20-ABC-SP
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Bracket Inspection
Check for looseness between extinguisher and bracket. The band clamp should shut tightly, compressing the band grommet.
Inspect the extinguisher and the bracket for wear caused by movement of the extinguisher within the bracket.
Examine entire bracket closely for loose or worn hinges or hinge-pins, bent or cracked bands, and worn or missing grommets.
Clean any pads that are oily or greasy.
Did you replace or repair all components that are missing, worn or damaged?
Sign off on the bracket inspection
1 Yearly Bracket Maintenance
Clean any dirt, ice, or other foreign material from the extinguisher and bracket
Remove the extinguisher from the bracket and clean the extinguisher surface where the bracket pads contact it
Examine the bracket pads which hold the extinguisher in place. Clean the pad surfaces to maintain their gripping power on the extinguisher. Check the pads for resiliency, and replace if necessary
Inspect the bracket. If it has been bent, replace it. If it has been cracked, repair or replace it
If any welding is performed, take steps to protect the bracket pads from excessive heat
Grease each moving part of the bracket arm and test its action. The bracket must be able to hold the extinguisher firmly, but release easily when necessary
Check to see that the bracket is firmly mounted. Tighten or replace mounting fasteners, or re-weld connections as needed
Avoid possible rust damage by cleaning and painting wherever bare steel is exposed
Following extinguisher maintenance, secure the extinguisher in its bracket. If the bracket does not hold the extinguisher securely or the bracket is difficult to close, replace the affected part and/or bracket
1 Yearly Fire Extinguisher Maintenance
NOTICE: Always be alert for any indications of damage or in-operability in the unit.
Extinguisher is in its designated place, conspicuous, readily accessible and immediately available in the event of fire.
Extinguisher removed from its wall hanger or bracket. Check the securement of the hanger or bracket.
NOTICE: Extinguishers out of service for maintenance or recharge shall be replaced by spare extinguishers of the same type and at least equal rating.
Check the date of manufacture stamped on the shell or the date of last hydrostatic test on the label affixed to the extinguisher.
Invert the extinguisher and open the nozzle to ensure that any pressure is relieved from the shell.
Return extinguisher to the upright position, place the hose in its normal position and insert the nozzle in the holder.
Examine the dry chemical shell and all other external components for evidence of corrosion, mechanical damage, or the presence of welding, soldering or brazing repairs.
Check the nameplates for legibility, looseness or corrosion.
Bracket Adjustment
Warning: Improper adjustment may cause damage to the bracket or extinguisher.
Extinguisher is firmly in the bracket base
Clamp arm is level and arranged for best fit
Handle is opened to the correct width
T-bolt length is adjusted to fit into the handle notches
T-bolt is properly seated and square to the bracket back
Handle is carefully closed, clamping the extinguisher into the bracket
Bracket adjustment is checked for any play or tension issues
Sign off on the bracket adjustment
Cartridge Receiver Puncture Pin Replacement
Cartridge removed from extinguisher
Retaining roll pin removed from lever
Old puncture pin removed by pushing downward
New puncture pin installed
Roll pin installed in reverse procedure
Puncture pin travels freely by operating the lever
Access the parts list for your equipment in MaintainX.
12.0 Oz Spray Can – Primer
79729
3M #10 Contact Adhesive
59348
9.0 Oz Spray Can – Red Enamel
79730
9.0 Oz Spray Can – Red Epoxy-CR
79731
Agent Funnels
699
12.0 Oz Spray Can – Primer
79729
3M #10 Contact Adhesive
59348
9.0 Oz Spray Can – Red Enamel
79730
9.0 Oz Spray Can – Red Epoxy-CR
79731
Agent Funnels
699
12.0 Oz Spray Can – Primer
79729
3M #10 Contact Adhesive
59348
9.0 Oz Spray Can – Red Enamel
79730
9.0 Oz Spray Can – Red Epoxy-CR
79731
Agent Funnels
699
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX