Ansul Fire Extinguisher 10
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Bracket Inspection
Inspection of the bracket should be performed whenever extinguisher inspection is performed.
Check for looseness between extinguisher and bracket. The band clamp should shut tightly, compressing the band grommet.
Inspect the extinguisher and the bracket for wear caused by movement of the extinguisher within the bracket.
Examine entire bracket closely for loose or worn hinges or hinge-pins, bent or cracked bands, and worn or missing grommets.
Clean any pads that are oily or greasy.
Avoid future damage by replacing or repairing all components that are missing, worn or damaged.
Sign off on the bracket inspection
1 Yearly Bracket Maintenance
Clean any dirt, ice, or other foreign material from the extinguisher and bracket
Remove the extinguisher from the bracket and clean the extinguisher surface where the bracket pads contact it
Examine the bracket pads which hold the extinguisher in place. Clean the pad surfaces to maintain their gripping power on the extinguisher. Check the pads for resiliency, and replace if necessary
Inspect the bracket. If it has been bent, replace it. If it has been cracked, repair or replace it
If any welding is performed, take steps to protect the bracket pads from excessive heat
Grease each moving part of the bracket arm and test its action. The bracket must be able to hold the extinguisher firmly, but release easily when necessary
Check to see that the bracket is firmly mounted. Tighten or replace mounting fasteners, or re-weld connections as needed
Avoid possible rust damage by cleaning and painting wherever bare steel is exposed
Following extinguisher maintenance, secure the extinguisher in its bracket. If the bracket does not hold the extinguisher securely or the bracket is difficult to close, replace the affected part and/or bracket
1 Yearly Fire Extinguisher Maintenance
NOTICE: Always be alert for any indications of damage or in-operability in the unit.
Extinguisher is in its designated place, conspicuous, readily accessible and immediately available in the event of fire.
Extinguisher is securely hanged or bracketed.
Date of manufacture or last hydrostatic test does not exceed the test interval (twelve years) specified in the latest edition of NFPA 10.
Extinguisher is free of obvious physical damage, corrosion, leakage, or clogged nozzle.
Nameplates are legible, not loose or corroded.
Cartridge seal is not punctured and it is the proper ANSUL cartridge and has the proper ANSUL seal.
Cartridge weight is not 1/4 oz (7.1 g) for Model 10 or 1/2 oz (14.2 g) for Models 20/30 less than stamped on the cartridge.
Puncture lever works freely and the cutting edge is sharp.
Bracket Adjustment
Warning: Improper adjustment may cause damage to the bracket or extinguisher.
Extinguisher is firmly in the bracket base
Clamp arm is level and arranged for best fit
Handle Adjustment
Handle is opened to the correct width
T-bolt length fits into the notches on the handle
T-bolt is properly seated and square to the bracket back
Handle closes properly, clamping the extinguisher into the bracket
Bracket Adjustment Check
Cartridge Receiver Puncture Pin Replacement
Cartridge removed from extinguisher
Retaining roll pin removed from lever
Old puncture pin removed by pushing downward
New puncture pin installed
Roll pin installed in reverse procedure
Puncture pin travels freely by operating the lever
Access the parts list for your equipment in MaintainX.
12.0 Oz Spray Can – Primer
79729
3M #10 Contact Adhesive
59348
9.0 Oz Spray Can – Red Enamel
79730
9.0 Oz Spray Can – Red Epoxy-CR
79731
Agent Funnels
699
12.0 Oz Spray Can – Primer
79729
3M #10 Contact Adhesive
59348
9.0 Oz Spray Can – Red Enamel
79730
9.0 Oz Spray Can – Red Epoxy-CR
79731
Agent Funnels
699
12.0 Oz Spray Can – Primer
79729
3M #10 Contact Adhesive
59348
9.0 Oz Spray Can – Red Enamel
79730
9.0 Oz Spray Can – Red Epoxy-CR
79731
Agent Funnels
699
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX