

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Thermo Fisher Electrode 8102BNUWP
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Electrode Cleaning
General Cleaning
Prepare cleaning solutions
Soak the electrode in the 0.1 M HCl or HNO3 solution for half an hour
Stir the acid solution at a moderate rate
Soak the electrode in the 1:10 dilution of household laundry bleach or the detergent solution for 15 minutes
Stir the bleach or detergent solution at a moderate rate
Is a refillable electrode used?
Soak the electrode in ROSS pH electrode storage solution or standard pH electrode storage solution for at least one hour
Refillable Electrode Maintenance
Electrode Maintenance
Electrode Inspection
Inspect the electrode for the following issues
Cleaning the Electrode
Rinse off any salt buildup with distilled water
Remove any membrane/junction deposits as directed in the General Cleaning section
Refillable Electrode Maintenance
Drain the reference chamber
Flush the reference chamber with fresh ROSS fill solution
Refill the chamber with fresh ROSS fill solution
Electrode Calibration
General Calibration Procedure
Consult the meter user guide for detailed instructions on pH calibration, manual pH calibration, and temperature compensation.
Refer to the PerpHecT meter user guide for instructions on temperature calibration and LogR temperature compensated pH measurements.
Is the meter set to automatically recognize the pH buffer at the measured temperature and an ATC probe is used?
One Buffer Calibration
Choose a buffer near expected sample pH and ensure it is at the same temperature as the sample.
Prepare the meter according to the meter user guide.
Rinse the electrode first with distilled water and then with the buffer being used for calibration.
Place the electrode into the buffer and set the meter to the pH value of the buffer at the measured temperature when the reading is stable.
Access the parts list for your equipment in MaintainX.
ROSS Fill Solution
810007
ROSS pH Electrode Storage Solution
810001
Standard pH Electrode Storage Solution
910001
Thermo Scientific Orion Stirrer Probe
96019
10% KNO3 Solution
900003
ROSS Fill Solution
810007
ROSS pH Electrode Storage Solution
810001
Standard pH Electrode Storage Solution
910001
Thermo Scientific Orion Stirrer Probe
96019
10% KNO3 Solution
900003
ROSS Fill Solution
810007
ROSS pH Electrode Storage Solution
810001
Standard pH Electrode Storage Solution
910001
Thermo Scientific Orion Stirrer Probe
96019
10% KNO3 Solution
900003
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













