MaintainX Asset Hub logo
EnterprisePricing
Ohaus

Ohaus Adventurer ™ Balances AX423N

Need answers fast?
Explore the manual using AI.

Ohaus Adventurer ™ Balances AX423N
Ohaus Adventurer ™ Balances AX423N

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Ohaus Adventurer ™ Balances AX423N

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Ohaus Adventurer ™ Balances AX423N

Ohaus Adventurer ™ Balances AX423N

Create an account to install this asset package.

Maintenance Plans for Ohaus Adventurer ™ Balances Model AX423N

Integrate maintenance plans directly into your work orders in MaintainX.

Adventurer Precision Housing Removal

Check mark

Initial Component Removal

Check mark

Remove the balance weighing pan and securely set it aside

Check mark

Remove the balance Pan Support

Check mark

Windring Removal

Check mark

Gently release the two hinges securing the Windring to the balance top housing

Check mark

Remove the balance Windring

Check mark

Follow the instructions for removing Adventurer housing from page 3-4

Run this procedureArrow right

Adventurer Type Strain Gage Load Cell Replacement

Check mark

Preparation

Check mark

Ensure the device is powered off

Check mark

Gather necessary tools for replacement

Check mark

Accessing the Load Cell

Check mark

Remove the balance load cell metal cover

Check mark

Verify visibility of the Strain Gage load cell

Check mark

Disconnecting the Load Cell

Check mark

Locate the cable connecting the Strain Gage load cell to the balance main PCBA

Check mark

Remove the cable connecting the Strain Gage load cell to the balance main PCBA

Run this procedureArrow right

Adventurer Type Conventional Mfr Load Cell Replacement

Check mark

Preparation

Check mark

Remove the balance load cell metal cover

Check mark

Load Cell Disconnection

Check mark

Locate and remove the cables connecting the Conventional MFR load cell to the balance main PCBA

Check mark

Load Cell Removal

Check mark

Locate and remove the screws securing the Conventional MFR Cell to the bottom housing

Run this procedureArrow right

Main Printed Circuit Board Replacement

Check mark

Cable Disconnection

Check mark

Disconnect the following cables

Check mark

Main PC Board Removal

Check mark

Remove the screws securing the Main PC Board to the Base

Check mark

Main PC Board Installation

Check mark

Install replacement Main PC Board in reverse order

Check mark

Check if the LCD display on the new board is clear of protective plastic

Check mark

Reassemble the balance

Check mark

Finalization and Testing

Run this procedureArrow right

Adventurer Analytical Housing Removal

Check mark

Turn off the balance and unplug the power cord

Check mark

Preliminary Steps for a balance with a Draft Shield

Check mark

Remove the weighing pan and wind ring and set aside

Check mark

Remove the EMC plate by removing the two screws holding it to the balance top housing

Check mark

Remove the two screws securing the draft shield housing to the balance

Check mark

Remove the balance top housing

Check mark

Remove the keypad membrane cable by unfastening the connector

Check mark

Remove the TFT LCD cable by lifting the connector lock upwards

Check mark

Detach the latch located at the right front of the balance

Run this procedureArrow right

Parts for Ohaus Adventurer ™ Balances AX423N

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Sp Assembly Top Frame, Ax

30111789

Sp Glasses Kit, Ax

30111786

Sp Plate Bottom, Ax

30111788

Sp Hardware Kit, Ax

30111782

Pan Assy, 90Mm Ex

83033640

Sp Assembly Top Frame, Ax

30111789

Sp Glasses Kit, Ax

30111786

Sp Plate Bottom, Ax

30111788

Sp Hardware Kit, Ax

30111782

Pan Assy, 90Mm Ex

83033640

Sp Assembly Top Frame, Ax

30111789

Sp Glasses Kit, Ax

30111786

Sp Plate Bottom, Ax

30111788

Sp Hardware Kit, Ax

30111782

Pan Assy, 90Mm Ex

83033640

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Ohaus

Explore Other Assets