The Hussmann Q-Series Medium Temperature Self Contained Merchandiser Q2SSM6S is designed for efficient refrigeration in retail environments. This reliable unit features advanced temperature control and energy-saving technologies, ensuring optimal product preservation and visibility. Ideal for showcasing perishable goods, it combines functionality with modern design.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Hussmann Q-Series Medium Temperature Self Contained Merchandiser Q2SSM6S
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Coils Cleaning
Warning: Always wear gloves and protective eye wear when cleaning near sharp coil fins and dust particles.
Check if condenser coils are clean
If coils are dirty, proceed to next step
Clean the coils using a vacuum cleaner with a wand attachment and a soft (non-metallic) brush
Check if the coils are clean after cleaning
Sign off on the coil cleaning
1 Weekly Merchandiser Cleaning
CARE AND CLEANING
• Long life and satisfactory performance of any equipment is dependent upon the care it receives. To ensure long life, proper sanitation and minimum maintenance costs, these merchandisers should be thoroughly cleaned, all debris removed and the interiors washed down, weekly.
Exterior Surfaces • The exterior surfaces must be cleaned with a mild detergent and warm water to protect and maintain their attractive finish. Never use abrasive cleansers or scouring pads.
Interior Surfaces
• The interior surfaces may be cleaned with most domestic detergents, ammonia based cleaners and sanitizing solutions with no harm to the surface. Self contained models empty into a limited capacity evaporation pan, which will overflow if excess water is used in cleaning.
Do NOT Use:
•Abrasive cleansers and scouring pads, as these will mar the finish.
•Coarse paper towels on coated glass.
•Ammonia-based cleaners on acrylic parts.
3 Monthly Merchandiser Maintenance
Record any complaints or issues from the store manager
Check unit for any damage, vibrations or abnormal noise
Verify unit is level side to side and front to rear
Confirm refrigerant lines are properly secured and not touching or rubbing other lines, wires or frame work
Verify fan motors and motor mounts are tight
Confirm fan blade/s are tight and not rubbing or hitting
Make sure all electrical connections, factory and field, are tight
Verify electrical connections at lamps are secure and dry
Check for and replace any frayed or chaffed wiring
6 Monthly Discharge Air Louvers Cleaning
Warning: Be careful not to damage the louvers during cleaning
Are the louvers dirty?
Choose the cleaning method used
Is all water removed from the louvers cells before replacing?
Are the louvers damaged during cleaning?
Sign off on the louver cleaning
6 Monthly Merchandiser Maintenance
Clean evaporator coil/s and fan blade/s. Do not use an acid base cleaner. Rinse off any cleaner residue.
Clean discharge air honeycombs or grilles. Do not use an acid base cleaner. Rinse off any cleaner residue.
Clean condenser coil/s and fan blade/s. Do not use an acid base Cleaner. Rinse off any cleaner residue.
Clean condensate drain pan and drain line.
Verify condensate drain lines are clear and functioning.
Record voltage reading at unit with unit off.
Record voltage reading with unit running.
Record compressor amp draw.
Record defrost heater voltage and amp draw.
Access the parts list for your equipment in MaintainX.
Air Deck Pan (Bottom)
0552846
Air Deck Pan (Top)
0552840
Aluminum Bumper Base
175035002
Aluminum Fan Blade (6.70", 15º)
0428111
Back Panel Chimney Q2 6 ft
0555349
Air Deck Pan (Bottom)
0552846
Air Deck Pan (Top)
0552840
Aluminum Bumper Base
175035002
Aluminum Fan Blade (6.70", 15º)
0428111
Back Panel Chimney Q2 6 ft
0555349
Air Deck Pan (Bottom)
0552846
Air Deck Pan (Top)
0552840
Aluminum Bumper Base
175035002
Aluminum Fan Blade (6.70", 15º)
0428111
Back Panel Chimney Q2 6 ft
0555349
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX