Endress+Hauser Sensor pH and ORP CPS76D
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Sensor Cleaning
Clean the sensor before each calibration.
Clean away fouling on the sensor as follows depending on the type of fouling:
1. Oily and greasy films:
Clean with grease remover, e.g. alcohol, as well as hot water and (alkaline) agents containing surfactants (e.g. dishwashing detergent).
2. Lime, cyanide and metal hydroxide buildup and low solubility organic buildup:
Dissolve buildup with diluted hydrochloric acid (3 %) and then rinse thoroughly with plenty of clear water.
3. WARNING
Thiocarbamide
Harmful if swallowed. Limited evidence of carcinogenicity. Possible risk of harm to the unborn child. Dangerous for the environment with long-term effects!
Sensor Calibration and Measurement
Warning: Ensure the sensor is immersed in medium for at least 24 hours before use if stored dry.
Is the sensor stored in a KCl solution (3 mol/l) or buffer solution (pH 7.00)?
Note: Calibration frequency depends on operating conditions (fouling, chemical load).
Note: pH or ORP sensors with Memosens technology do not need to be calibrated when first connected.
Two-point calibration is required for pH sensors.
Is the sensor immersed in a defined buffer solution (e.g. pH 7 or 220 mV)?
Enter the pH value or mV value of the buffer solution.
Has the calibration started?
Has the value stabilized?
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX