The Daikin Packaged Rooftop System DPS010AHHE2DC-4 is a high-efficiency HVAC solution designed for commercial applications. This robust system offers reliable heating and cooling performance, ensuring optimal indoor climate control while minimizing energy consumption. Ideal for various building types, it combines advanced technology with user-friendly features.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Packaged Rooftop System DPS010AHHE2DC-4
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Compressor Ground Fault Interrupter Service
Warning: This service requires trained personnel with PPE!
Is the current sensing donut on the power wires to the compressor(s) functional?
Is the PCB functional?
Is the device monitoring the balance between the three phase power and the neutral conductor?
Note: The device is not intended to provide overcurrent or short circuit protection to the equipment.
Is the device opening the 120V controls circuit in a fault condition?
Is there an open condition on the ground fault interrupter?
Report any issues found during the service
Sign off on the Compressor Ground Fault Interrupter Service
1 Monthly Coated Coil Cleaning
WARNING: Prior to cleaning the unit, turn off and lock out the main power switch to the unit and open all access panels
The following cleaning procedures are recommended as part of the routine maintenance activities for Option E Coated Coils. Documented routine cleaning of Option E Coated Coils is required to maintain warranty coverage.
1. Remove Surface Loaded Fibers: Surface loaded fibers or dirt should be removed prior to water rinse to prevent further restriction of airflow.
2. If unable to back wash the side of the coil opposite that of the coils entering air side, then surface loaded fibers or dirt should be removed with a vacuum cleaner. If a vacuum cleaner is not available, a soft non-metallic bristle brush may be used. In either case, the tool should be applied in the direction of the fins. Coil surfaces can be easily damaged (fin edges bent over) if the tool is applied across the fins.
NOTE: Use of a water stream, such as a garden hose, against a surface loaded coil will drive the fibers and dirt into the coil. This will make cleaning efforts more difficult. Surface loaded fibers must be completely removed prior to using low velocity clean water rinse.
3. Periodic Clean Water Rinse: A monthly clean water rinse is recommended for coils that are applied in coastal or industrial environments to help to remove chlorides, dirt and debris. An elevated water temperature (not to exceed 130°F) will reduce surface tension, increasing the ability to remove chlorides and dirt. Pressure washer PSI must not exceed 900 psig and the nozzle should remain at least 1 foot from the coil to avoid damaging fin edges.
Surface loaded fibers or dirt removed?
Clean water rinse performed?
Enter the water temperature used for rinse
Fan Maintenance
The supply, condenser and exhaust fan motors are permanently lubricated and require no periodic lubrication.
Each unit as shipped is trim balanced to operate smoothly. To provide satisfactory operation after shipping and installation, use accepted industry guidelines for field balancing fans.
NOTE: Excessive vibration from any cause contributes to premature fan and motor bearing failure. Monitor overall vibration levels every six months of operation. An increase in levels is an indication of potential trouble.
Vibration Causes
Enter the vibration level of the fan
Did the fan pass the vibration test?
Enter any issues found during the test
Sign off on the fan maintenance
1 Monthly Rooftop System Maintenance
Check cabinet air filters and replace if dirty
After heavy snowfall verify that combustion air intakes are not blocked by snow
Periodically check during periods of snow accumulation as drifting may also lead to combustion air intake blockage
Open a door on each section and verify that no moisture or debris is accumulating in the unit monthly during preparation for storage (p.137);
1 Yearly Rooftop System Maintenance
Check vent terminal screens for blockages and accumulation
Heater and the Venting System shall be inspected once a year by a qualified service agency.
Check all valves, piping and connections of Gas Train for leakage with a rich soap solution or UL 913 combustible gas leak detector. Any bubbling is considered a leak and must be eliminated.
Inspect and clean flame rod, ignition electrode, and burner manifold
Remove any debris that may have accumulated in the drain pain and drain
Access the parts list for your equipment in MaintainX.
Furnace Control
VB1200
Natural Gas Fired Furnace
910166415
Natural Gas Fired Furnace
910166418
Natural Gas Furnace
404231252
Staged Furnace
300049581
Furnace Control
VB1200
Natural Gas Fired Furnace
910166415
Natural Gas Fired Furnace
910166418
Natural Gas Furnace
404231252
Staged Furnace
300049581
Furnace Control
VB1200
Natural Gas Fired Furnace
910166415
Natural Gas Fired Furnace
910166418
Natural Gas Furnace
404231252
Staged Furnace
300049581
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX