MaintainX Asset Hub logo
EnterprisePricing
Daikin

Daikin Outdoor Unit Cooling Only Air Conditioner RN60CXV1

Need answers fast?
Explore the manual using AI.

Daikin Outdoor Unit Cooling Only Air Conditioner RN60CXV1
Daikin Outdoor Unit Cooling Only Air Conditioner RN60CXV1

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Outdoor Unit Cooling Only Air Conditioner RN60CXV1

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Outdoor Unit Cooling Only Air Conditioner RN60CXV1

Daikin Outdoor Unit Cooling Only Air Conditioner RN60CXV1

Create an account to install this asset package.

Maintenance Plans for Daikin Outdoor Unit Cooling Only Air Conditioner Model RN60CXV1

Integrate maintenance plans directly into your work orders in MaintainX.

2 Weekly Air Filter Maintenance

Check mark

WARNING: Disconnect from main supply before servicing the air conditioner.

Check mark

CAUTION: Don’t touch the metal parts of the indoor unit. It may cause an injury.

Check mark

When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully.

Check mark

When removing or attaching the front panel, support the panel securely with hand to prevent from it falling.

Check mark

For cleansing, do no use hot water above 40°C, benzene, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff.

Check mark

After cleaning, make sure that the front panel is securely fixed.

Check mark

Remove any dust adhering to the filter by using a vacuum cleaner or wash in lukewarm water (below 40°C) with a neutral cleaning detergent.

Check mark

Rinse the filter well and dry before placing it back onto the unit.

Check mark

Note: Never use gasoline, volatile substances or chemicals to clean the filter.

Run this procedureArrow right

1 Monthly Indoor / Outdoor Coil Check

Check mark

WARNING: Disconnect from main supply before servicing the air conditioner.

Check mark

The unit is designed to give long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention.

Check mark

Check and remove the dirt between the fins.

Check mark

Check and remove any obstacles which hinder air flow through the indoor or outdoor.

Check mark

CAUTION: Don’t touch the metal parts of the indoor unit. It may cause an injury.

Check mark

When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully.

Check mark

When removing or attaching the front panel, support the panel securely with hand to prevent from it falling.

Check mark

For cleansing, do no use hot water above 40°C, benzene, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff.

Check mark

After cleaning, make sure that the front panel is securely fixed.

Run this procedureArrow right

6 Monthly Compressor Check

Check mark

WARNING: Disconnect from main supply before servicing the air conditioner.

Check mark

CAUTION: Don’t touch the metal parts of the indoor unit. It may cause an injury.

Check mark

When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully.

Check mark

When removing or attaching the front panel, support the panel securely with hand to prevent from it falling.

Check mark

For cleansing, do no use hot water above 40°C, benzene, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff.

Check mark

After cleaning, make sure that the front panel is securely fixed.

Check mark

Check for refrigerant leak at joint and fitting.

Check mark

Sign off on the compressor check

Run this procedureArrow right

3 Monthly Air Intake Coil Maintenance

Check mark

Warning: This maintenance check requires qualified Air Conditioner Service Technicians!

Check mark

Caution: Do not charge OXYGEN, ACETYLENE OR OTHER FLAMMABLE and poisonous gases into the unit when performing a leakage test or an airtight test. These gases could cause severe explosion and damage if exposed to high temperature and pressure.

Check mark

Check and clean air intake coil surface.

Check mark

Is the unit installed in areas subjected to much oil mist and dust?

Check mark

If yes, the coils must be regularly cleaned to ensure sufficient heat exchange and proper operation.

Check mark

Perform a leakage test with nitrogen or refrigerant.

Check mark

Perform an airtight test with nitrogen or refrigerant.

Check mark

Sign off on the air intake coil maintenance

Run this procedureArrow right

2 Monthly Power Supply Check

Check mark

WARNING: Disconnect from main supply before servicing the air conditioner.

Check mark

CAUTION: Don’t touch the metal parts of the indoor unit. It may cause an injury.

Check mark

When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully.

Check mark

When removing or attaching the front panel, support the panel securely with hand to prevent from it falling.

Check mark

For cleansing, do no use hot water above 40°C, benzene, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff.

Check mark

After cleaning, make sure that the front panel is securely fixed.

Check mark

Check the running current for indoor unit

Check mark

Check the running current for outdoor unit

Check mark

Check the voltage for indoor unit

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets