MaintainX Logo
EnterprisePricing
Daikin

Daikin Air Handler CAH004GDAM

Need answers fast?
Explore the manual using AI.

Daikin Air Handler CAH004GDAM
Daikin Air Handler CAH004GDAM

The Daikin Air Handler CAH004GDAM is a high-efficiency air handling unit designed for optimal indoor climate control. This model features advanced technology for reliable performance, ensuring effective air distribution and comfort in industrial applications. Ideal for various settings, it supports efficient heating and cooling solutions.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Air Handler CAH004GDAM

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Air Handler CAH004GDAM

Daikin Air Handler CAH004GDAM

Create an account to install this asset package.

Maintenance Plans for Daikin Air Handler Model CAH004GDAM

Integrate maintenance plans directly into your work orders in MaintainX.

Fan Drive Belt Maintenance

Check mark

Warning: Moving belt and fan can cause severe personal injury or death. Always ensure safety measures are in place.

Check mark

Is the belt tension at the lowest tension at which the belt does not slip under peak load conditions?

Check mark

Measure the belt span

Check mark

Measure the force applied to the belt tension checker

Check mark

Does the measured force match the required values?

Check mark

Is the belt free from foreign material that can cause slippage?

Check mark

Is the V-drive inspected and adjusted if necessary?

Check mark

Warning: Do not apply belt dressing. This can damage the belt and cause early failure.

Check mark

Are the belt and fan guards on plenum fan units always in place?

Run this procedureArrow right

Filter Maintenance

Check mark

Replace front load filter option

Check mark

Filters removed and replaced from inside the unit

Check mark

Filters fully seated in the frame after installation

Check mark

Clean Filter Gauges

Check mark

Pressure drop for installed filters

Check mark

Typical filter pressure drop for clean filters at rated air flow

Check mark

Final pressure drop for front loaded filters

Check mark

Prefilters removed to check the pressure drop of the final filters

Check mark

Sign off on the filter maintenance

Run this procedureArrow right

1 Yearly Coil Maintenance

Check mark

CAUTION: Sharp fin edges are a potential injury hazard. Avoid contact with them

Check mark

Check coils for cleanliness

Check mark

To obtain maximum performance, the coil must be clean

Check mark

Check once a year under normal operating conditions and, if dirty, brush or vacuum clean.

Check mark

Use a chemical coil cleaner on multiple row coils

Check mark

Read and follow the chemical cleaner's instructions as some cleaners may contain harsh chemicals

Check mark

Take care not to damage fins while cleaning.

Check mark

CAUTION-Fin edges are sharp

Run this procedureArrow right

Fan Drive Maintenance

Check mark

WARNING: Before servicing fans, lock out and tag out all power to the unit. Fans or belts can cause severe personal injury or death

Check mark

WARNING: Do not open the hinged access door and screw-fastenerd access panels while the unit is operating. Moving parts and strong suction forces can cause severe personal injury or death

Check mark

Adjust the fan drive

Check mark

Replace the variable pitched motor sheave with a properly sized, fixed sheave

Check mark

Replace the adjustable sheaves with fixed sheaves

Check mark

Measure the diameter of the V-belt outer surface where it passes around the sheave (pitch diameter)

Check mark

Calculate fan speed from the motor nameplate rpm

Check mark

Sign off on the fan drive maintenance

Run this procedureArrow right

2000 Hours Motor Bearings Lubrication

Check mark

CAUTION: Bearing overheating potential. Can damage the equipment. Do not over lubricate bearings. Use only a high grade mineral grease with a 200°F safe operating temperature.

Check mark

NOTE: Direct-Drive Class Il fans that are supplied with TECO motors have double shielded bearings on frame sizes 140T-280T. These bearings are pre-packed with a long life grease and are not regreaseable. Larger frame size TECO motors are regreaseable and follow the same lubrication recommendations as all other motors

Check mark

Motor bearings and ball bearings lubricated

Check mark

Select the lubricant used

Check mark

Enter the amount of lubricant used

Check mark

Upper and lower grease plugs cleaned

Check mark

Clean grease added with a low pressure gun

Check mark

Motor run for five minutes before replacing the plugs

Check mark

Sign off on the motor bearings lubrication

Run this procedureArrow right

Parts for Daikin Air Handler CAH004GDAM

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Replacement Bulb

205484001

Replacement Bulb

205484101

Replacement Bulb

205484201

Replacement Bulb

205484001

Replacement Bulb

205484101

Replacement Bulb

205484201

Replacement Bulb

205484001

Replacement Bulb

205484101

Replacement Bulb

205484201

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets