The Daikin Air Handler CAC077GBAM is a high-efficiency air handling unit designed for optimal climate control in commercial settings. With advanced features and reliable performance, this model ensures effective air distribution and energy savings, making it an ideal choice for HVAC applications.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Air Handler CAC077GBAM
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Bub Replacement
WARNING: Personal Injury Hazard. Power supply can cause electrical shock. Always disconnect all power to unit before servicing
WARNING: UV-C exposure is harmful to the skin and eyes. Looking at an illuminated UV-C bulb can cause permanent blindness. UV-C skin exposure can cause cancer
WARNING: Fluorescent bulbs contain mercury, which can cause personal injury if breathed or ingested. Use appropriate protective gear to clean up broken bulbs
Verify the UV lights are off by using the view window
Disconnect power to the power receptacle before servicing
Verify the power is disconnected
Before opening the access panels, use the viewing window to make sure the UV lights are off
Before handling, allow bulbs to cool for 5 minutes
Grasp body of bulb firmly at each end
1 Yearly Coil Maintenance
CAUTION: Sharp fin edges are a potential injury hazard. Avoid contact with them
Check coils for cleanliness
To obtain maximum performance, the coil must be clean
Check once a year under normal operating conditions and, if dirty, brush or vacuum clean.
Use a chemical coil cleaner on multiple row coils
Read and follow the chemical cleaner's instructions as some cleaners may contain harsh chemicals
Take care not to damage fins while cleaning.
CAUTION-Fin edges are sharp
6 Monthly Air Handler Check
Check all moving parts for wear
Check bearing collar, sheave, and wheel hub setscrews, sheave capscrews, and bearing hold-down bolts for tightness
Annually check and snug all electrical connections
Inspect for signs of water damage such as corrosion and repair if necessary
Check ground conductor and connection integrity and correct if needed
Pitch Key Sheave Maintenance
Loosen setscrews B and C in moving parts of sheave and pull out external key E
Adjust sheave pitch diameter for desired speed
Replace external key E and securely tighten setscrews B over key and setscrews C into keyway in fixed half of the sheave
Put on belts and adjust tension
Make future adjustments by loosening the belt tension and increasing or decreasing the pitch diameter of the sheave as required
Adjust both halves of the two-groove sheaves by the same number of turns from closed position
Verify that all keys are in place and that all se screws are tight before starting drive
Check setscrews and belt tension after 24 hours service
Sign off on the Pitch Key Sheave Maintenance
Fan Drive Belt Maintenance
Warning: Moving belt and fan can cause severe personal injury or death. Always ensure safety measures are in place.
Is the belt tension at the lowest tension at which the belt does not slip under peak load conditions?
Measure the belt span
Force applied to the belt tension checker
Does the force applied match the required values?
Is the belt free from foreign material that can cause slippage?
Is the V-drive inspected and adjusted if necessary?
Warning: Do not apply belt dressing. This can damage the belt and cause early failure.
Are the belt and fan guards on plenum fan units always in place?
Access the parts list for your equipment in MaintainX.
Replacement Bulb
205484001
Replacement Bulb
205484201
Replacement Bulb
205484101
Replacement Bulb
205484001
Replacement Bulb
205484201
Replacement Bulb
205484101
Replacement Bulb
205484001
Replacement Bulb
205484201
Replacement Bulb
205484101
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX