MaintainX Logo
EnterprisePricing
Daikin

Daikin Air Handler CAC077GBAM

Need answers fast?
Explore the manual using AI.

Daikin Air Handler CAC077GBAM
Daikin Air Handler CAC077GBAM

The Daikin Air Handler CAC077GBAM is a high-efficiency air handling unit designed for optimal climate control in commercial settings. With advanced features and reliable performance, this model ensures effective air distribution and energy savings, making it an ideal choice for HVAC applications.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Air Handler CAC077GBAM

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Air Handler CAC077GBAM

Daikin Air Handler CAC077GBAM

Create an account to install this asset package.

Maintenance Plans for Daikin Air Handler Model CAC077GBAM

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Bub Replacement

Check mark

WARNING: Personal Injury Hazard. Power supply can cause electrical shock. Always disconnect all power to unit before servicing

Check mark

WARNING: UV-C exposure is harmful to the skin and eyes. Looking at an illuminated UV-C bulb can cause permanent blindness. UV-C skin exposure can cause cancer

Check mark

WARNING: Fluorescent bulbs contain mercury, which can cause personal injury if breathed or ingested. Use appropriate protective gear to clean up broken bulbs

Check mark

Verify the UV lights are off by using the view window

Check mark

Disconnect power to the power receptacle before servicing

Check mark

Verify the power is disconnected

Check mark

Before opening the access panels, use the viewing window to make sure the UV lights are off

Check mark

Before handling, allow bulbs to cool for 5 minutes

Check mark

Grasp body of bulb firmly at each end

Run this procedureArrow right

1 Yearly Coil Maintenance

Check mark

CAUTION: Sharp fin edges are a potential injury hazard. Avoid contact with them

Check mark

Check coils for cleanliness

Check mark

To obtain maximum performance, the coil must be clean

Check mark

Check once a year under normal operating conditions and, if dirty, brush or vacuum clean.

Check mark

Use a chemical coil cleaner on multiple row coils

Check mark

Read and follow the chemical cleaner's instructions as some cleaners may contain harsh chemicals

Check mark

Take care not to damage fins while cleaning.

Check mark

CAUTION-Fin edges are sharp

Run this procedureArrow right

6 Monthly Air Handler Check

Check mark

Check all moving parts for wear

Check mark

Check bearing collar, sheave, and wheel hub setscrews, sheave capscrews, and bearing hold-down bolts for tightness

Check mark

Annually check and snug all electrical connections

Check mark

Inspect for signs of water damage such as corrosion and repair if necessary

Check mark

Check ground conductor and connection integrity and correct if needed

Run this procedureArrow right

Pitch Key Sheave Maintenance

Check mark

Loosen setscrews B and C in moving parts of sheave and pull out external key E

Check mark

Adjust sheave pitch diameter for desired speed

Check mark

Replace external key E and securely tighten setscrews B over key and setscrews C into keyway in fixed half of the sheave

Check mark

Put on belts and adjust tension

Check mark

Make future adjustments by loosening the belt tension and increasing or decreasing the pitch diameter of the sheave as required

Check mark

Adjust both halves of the two-groove sheaves by the same number of turns from closed position

Check mark

Verify that all keys are in place and that all se screws are tight before starting drive

Check mark

Check setscrews and belt tension after 24 hours service

Check mark

Sign off on the Pitch Key Sheave Maintenance

Run this procedureArrow right

Fan Drive Belt Maintenance

Check mark

Warning: Moving belt and fan can cause severe personal injury or death. Always ensure safety measures are in place.

Check mark

Is the belt tension at the lowest tension at which the belt does not slip under peak load conditions?

Check mark

Measure the belt span

Check mark

Force applied to the belt tension checker

Check mark

Does the force applied match the required values?

Check mark

Is the belt free from foreign material that can cause slippage?

Check mark

Is the V-drive inspected and adjusted if necessary?

Check mark

Warning: Do not apply belt dressing. This can damage the belt and cause early failure.

Check mark

Are the belt and fan guards on plenum fan units always in place?

Run this procedureArrow right

Parts for Daikin Air Handler CAC077GBAM

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Replacement Bulb

205484001

Replacement Bulb

205484201

Replacement Bulb

205484101

Replacement Bulb

205484001

Replacement Bulb

205484201

Replacement Bulb

205484101

Replacement Bulb

205484001

Replacement Bulb

205484201

Replacement Bulb

205484101

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets