Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Carlyle Compressor Reciprocating Compressor 06DM3136
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Compressor Maintenance
Inspect oil for discoloration
Inspect oil for acidity
If oil stays clean and acid-free, the system is clean. If oil shows signs of contamination, follow the next steps.
Did you change the oil?
Did you change the filter-drier?
Did you clean the suction strainer?
If filter-drier or suction strainer is dirty or discolored, repeat this step until system is cleaned.
Sign off on the daily compressor maintenance
Bearing Head Assembly Maintenance
Warning: This maintenance check requires trained personnel with PPE!
Oil pressure tap located in the bearing head assembly?
Oil pump assembly contained in the pump end bearing head aluminum casting?
Pump end main bearing is a machined part of the casting?
No insert bearing is required.
Four (4) cap screws from the bearing head cover plate removed?
Oil feed guide vane and spring removed?
Two (2) drive segment cap screws from the end of the crankshaft removed?
Eight (8) cap screws holding the bearing head assembly to the crankcase removed?
Cylinder Head and Valve Plate Assembly Maintenance
REMOVE, INSPECT AND REPLACE CYLINDER HEAD AND VALVE PLATE ASSEMBLY
To test for leaking discharge valves or blown cylinder head or valve plate gaskets:
Pump compressor down.
Observe suction and discharge pressure equalization.
If valves are leaking or a gasket is blown, the pressure will equalize rapidly.
Maximum allowable discharge pressure drop is 3 psi per minute after initial drop of 10 to 15 psi in first half minute.
New reed valves may require 24 to 48 hour run-in time to seat completely.
A compressor bank (head) with a blown gasket can also usually be detected by touch since the head temperature will normally be much hotter than a bank with good gaskets.
If there is an indication of loss of capacity and discharge valves are functioning properly, remove valve plate assembly and inspect suction valves.
Initial 24 Hours Gear Cap Screws Maintenance
Warning: This procedure is for trained personnel only
Is the compressor with metal core gaskets?
If the compressor is with metal core gaskets, no re-torque is required
Did the gear cap screws lose hold-down torque?
If the gear cap screws lost hold-down torque, proceed to re-torque
Sign off on the gear cap screws maintenance
Initial 2 Hours Motor Inspection
Warning: This inspection requires trained personnel with PPE!
After 2 to 4 hours of operation, inspect compressor oil for discoloration and/or acidity.
Does the oil show signs of contamination?
If oil shows signs of contamination, replace oil and filter-driers and clean the suction strainer.
NOTE: When testing for moisture and acidity, be sure the test kit used is appropriate for the refrigerant (CFC, HCFC, or HFC) and the oil (mineral, alkylbenzene, or POE) in the system.
Select the type of refrigerant used
Select the type of oil used
Carrier’s Total Test Kit is accurate for CFC and HCFC air-conditioning applications. If used with POE oils, Total Test Kit will indicate acid, but is not an accurate indicator of moisture.
Sign off on the initial 2 hours motor inspection
Access the parts list for your equipment in MaintainX.
Adapter Package, (16 to 37 cfm)
06DA900072
Adapter Package, (50 to 99 cfm)
06EA660127
Baffle Plate, High Temperature Duty, (4) 1/2" Orifices
06EA660145
Baffle Plate, Low Temperature Duty, (3) 3/16" Orifices
06DA660103
Baffle Plate, Medium Temperature Duty, (3) 17/64" Orifices
06DA660104
Adapter Package, (16 to 37 cfm)
06DA900072
Adapter Package, (50 to 99 cfm)
06EA660127
Baffle Plate, High Temperature Duty, (4) 1/2" Orifices
06EA660145
Baffle Plate, Low Temperature Duty, (3) 3/16" Orifices
06DA660103
Baffle Plate, Medium Temperature Duty, (3) 17/64" Orifices
06DA660104
Adapter Package, (16 to 37 cfm)
06DA900072
Adapter Package, (50 to 99 cfm)
06EA660127
Baffle Plate, High Temperature Duty, (4) 1/2" Orifices
06EA660145
Baffle Plate, Low Temperature Duty, (3) 3/16" Orifices
06DA660103
Baffle Plate, Medium Temperature Duty, (3) 17/64" Orifices
06DA660104
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX