Bell & Gossett Pump NRF-45
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Pump Periodic Inspection
Periodic Inspection
Check for any visible leakage
Inspect for evidence of past leakage
Decide if the unit needs repair or replacement
Pump Maintenance
Removal of the Pump from Existing System for Replacement
Isolate the unit and control panel from the power supply, including the control circuit, before starting work.
Close the suction- and discharge-side valves (or drain the system if no valves are installed).
Let the water cool to a maximum of 100°F (38°C) before draining, then open the drain valve and leave it open until servicing is complete.
Loosen the conduit box cover screw and remove the cover.
Disconnect the electrical supply lines to the pump.
Confirm no electrical power is present at the motor leads before continuing.
Pump body pressure can be relieved by loosening the flange bolts and shifting the pump assembly slightly to let pressurized water escape.
Remove the flange nuts and bolts, or loosen the union ring nuts, then remove the pump from the piping.
Initial Pump Startup Check
System Preparation
Clean the closed heating and cooling systems
Drain the closed heating and cooling systems
Refill the closed heating and cooling systems with clean water
Measure the system pH
Is the system pH between 7 and 9?
Startup
Has the system been completely filled and vented?
Check for leaks at every gasketed or soldered joint
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX