Atlas Copco Oil-Water Separator OSC 300
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Weekly Condensate Check
Condensate Check Procedure
Compressor operational?
If compressor is not operational, report the issues to the maintenance team and stop the procedure
Enter the compressor operation time
Upload a photo of the test capsule
Compare the turbidity of the sample with the 10 ppm reference side on the test capsule
Sign off on the condensate check
1 Yearly Oleophilic Filter Replacement
Initially, the oleophilic filter will float almost completely on the condensate and only the bottom part will act as filtration medium. By absorbing more and more oil, the filter will sink and new filter material will be exposed to the condensate.
The filter must be replaced when the service indicator (see section Introduction) approaches the lid of the housing or when the condensate from the test outlet is less transparent than in the reference test capsule.
The lifetime of the filter depends on the amount of oil in the condensate.
Both filters should be replaced while servicing the unit. Filters should be replaced at least once per year irrespective of the loading.
Replacement instructions
1. Stop the compressor and close the air outlet valve. Switch off the voltage. Depressurize the outlet piping by opening the manual condensate drain.
2. Remove the lid of the housing and take out the oleophilic filter.
3. Only if necessary (see Problem solving, item 1), clean the inside of the condensate treatment device with water and tissue.
Do not use any form of soap or detergents as they could contain dispersants which deteriorate the ability to break oil/water emulsions.
1 Yearly Filter Replacement
Open the test valve and empty the cartridge into a bucket
Remove the screws of the cartridge and pull it away from the housing
Remove the ball valve at test outlet and place it to the new cartridge
Remove the plugs from the new cartridge and place them to used one
Place the cartridge near housing and start filling the cartridge with clean water
Push the cartridge into the housing and secure it with screws
Pour back the drained condensate into the housing
Fill the housing with clean water till water starts flowing out of condensate outlet
Inspect for leaks at the connection between housing and cartridge
Access the parts list for your equipment in MaintainX.
Alarm
8092 2849 29
Manifold
8070 2167 11
Spill Container
8102 0470 41
Alarm
8092 2849 29
Manifold
8070 2167 11
Spill Container
8102 0470 41
Alarm
8092 2849 29
Manifold
8070 2167 11
Spill Container
8102 0470 41
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX