Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Ametek Rheometer DVNext HA
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Screen Protector Replacement
Warning: Failure to properly install the screen protector may result in a disabled touch screen.
Turn off the DVNext rheometer (power down) prior to installation.
Clean the DVNext touch screen with the screen cloth prior to installation.
Identify Tab 1 and Tab 2 prior to removing any protective layer.
Peel back adhesive Tab 1, from the bottom, to expose half of the protector.
Do not touch the exposed surface of the adhesive side of the screen protector.
Align the screen protector to the bezel (frame) of the DVNext.
Completely remove Tab 1.
Lightly press the screen protector to the touch screen.
1 Yearly Viscosity Standard Fluid Replacement
Warning: This procedure requires trained personnel with PPE!
Date of last fluid replacement
Check for any contamination in the fluid
If contamination is found, proceed with fluid replacement
Upload a photo of the fluid before replacement
Upload a photo of the fluid after replacement
Sign off on the fluid replacement
Dispose of the old fluid in accordance with state, local and federal regulations
Do not re-certify Viscosity Standard Fluids. If needed, request a duplicate copy of the Certificate of Calibration from AMETEK Brookfield within two years of the purchase date.
Oscillation Check
Warning: This check requires trained personnel. Do not disturb the DV Rheometer during the check.
Spindle removed?
AutoZero performed?
Oscillation test started?
The device will now perform a series of steps automatically. This should take approximately 3 minutes.
Did the %Torque decrease smoothly?
Enter the final value of %Torque
Any value above 0.3 % or below -0.3% indicates that a calibration check should be performed.
Is a calibration check required?
Rheometer Calibration
Calibration Procedure for LV #1-3 (#61-63) and RV, HA, HB #1-6 AMETEK Brookfield Spindles
Viscosity standard fluid placed in the water bath?
DVNext lowered into measurement position?
Spindle attached to the Rheometer?
Viscosity standard fluid and spindle immersed for a minimum of 1 hour?
Temperature of the viscosity standard fluid
Viscosity reading equals the cP value on the fluid standard?
Calibration Procedure for a Small Sample Adapter
Proper amount of viscosity standard fluid put into the sample chamber?
Rheometer Cleaning
Ensure the instrument is in a clean, dry working environment (dust free, moderate temperature, low humidity, etc.)
Is the instrument on a level surface?
Are hands/fingers clean and free of sample residue?
Remove the spindle from the instrument prior to cleaning. Note left-handed thread. Severe instrument damage may result if the spindle is cleaned in place.
Do not apply excessive force when cleaning, which may result in bending spindles.
Instrument and Display: Cleaned with a dry, non-abrasive cloth?
Do not use solvents or cleaners. The instrument housing is manufactured from polycarbonate ABS. Clean Instrument housing with mild soap and water. Do not apply solvent to the instrument!
Immersed Components (spindles): Cleaned with a non-abrasive cloth and solvent appropriate for sample material?
Sign off on the rheometer cleaning
Access the parts list for your equipment in MaintainX.
4 GB Flash Drive
MFD-DVNX
Ball Bearing
XDVNTHBTBG0U00
Barcode Scanner
GV-1412
Base
GV-1201
Carrying Case
GV-1302Y
4 GB Flash Drive
MFD-DVNX
Ball Bearing
XDVNTHBTBG0U00
Barcode Scanner
GV-1412
Base
GV-1201
Carrying Case
GV-1302Y
4 GB Flash Drive
MFD-DVNX
Ball Bearing
XDVNTHBTBG0U00
Barcode Scanner
GV-1412
Base
GV-1201
Carrying Case
GV-1302Y
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX