The Alfa Laval Rotary Lobe Displacement Pump GHPD-422P is a high-performance pump designed for efficient fluid transfer in various industrial applications. Known for its reliability and durability, this model ensures optimal flow rates and minimal downtime, making it an essential asset for any processing facility.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Alfa Laval Rotary Lobe Displacement Pump GHPD-422P
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Weekly Pump Maintenance
Check the oil level in the gearcase (if applicable)
Check the mechanical seals for leakage and replace as necessary
Adjust the packed glands to control leakage
Check the oil seals for leakage
Check pumping pressures
Sign off on the weekly pump maintenance
2 Yearly Grease Replacement
Grease Replacement Procedure
Select the condition of the air
Enter the date of the next grease change
Was the grease successfully pumped into the rear of the gearcase?
Sign off on the grease replacement
3000 Hourly Lubrication Oil Replacement
Warning: The pump will NOT be supplied oil filled.
Enter the current hours of operation
Has the pump been operated for 150 hours?
If yes, proceed to oil replacement. If no, stop the procedure.
Upload a photo of the oil level in the sight glass.
Sign off on the oil replacement
Double Hyclean Seal Replacement
Firmly press on the o-rings (15) to the rear stationary faces (14) and locate them within the rear flush housing (16,17)
Carefully fit the rear seal housings (16,17) with the stationary face onto the shaft (22). (Caution: do not chip stationary face)
Push outboard rotary assembly (10,11) onto pump shaft (22) to the setting dimension (A) indicated on the assembly drawing and tighten set screws
Locate o-rings on the shaft (5, rotary) and within the rotorcase bore (1, stationary)
Press washer (7) underneath the inside drive pin into the rotary face (6) and gently slide onto the shaft, locating the pin in the shaft slot
Position the wave spring (3) over the stationary face (2), push into the rotorcase
Position front seal housing (9) onto rotorcase and hex head tighten screws (8). Be sure not to over tighten
Refit the rotorcase, using the shaft sleeve to ensure stationary seal is not chipped during assembly
Fit rear seal housings (16,17) and o-rings (12) to front flush housings (9) and tighten the hex nuts (18). (Caution: Be sure not to overtighten the hex nuts)
Flushed Hyclean Seal Replacement
– The seal rotary face is driven by a pin which locates in a slot on the shaft. A washer is located between the shaft shoulder and rotary face. A seal between the rotary face and shaft is provided by an 'O' ring.
– The stationary face is prevented from rotating as it has a flat side which sits in the rotorcase bore. Face to face contact is provided by a wave spring.
– Axial movement of the stationary face is prevented by a retaining clip. An 'O' ring within the rotorcase bore provides a seal onto the stationary face.
– A seal housing encloses the hyclean seal and is seal by an 'O' ring and retained to the rotorcase by socket head cap screws. A lip seal sits within the seal housing and runs on the rotary face, thus providing a seal.
CAUTION! SEAL FACES ARE BRITTLE - TAKE EXTREME CARE WHEN HANDLING. REMOVING THE FLUSHED HYCLEAN SEAL
REMOVING THE FLUSHED HYCLEAN SEAL
1. Carefully support and remove the rotorcase with the seal housing and stationary face still attached.
2. Slide the rotary face from the shaft.
3. Remove the seal housing screws to inspect the seal.
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX