Back

Power Supply Verification (ECCO Safety Group - Boise)

Checking power supply accuracy against a traceable reference keeps test and production equipment delivering the correct voltage.
ECCO Safety Group - Boise
11/19/2024

Power Supply Verification (ECCO Safety Group - Boise)

This procedure checks a power supply's voltage by comparing its displayed reading with a digital multimeter (DMM) measurement against set upper and lower tolerances, and recording the As Found and As Left results. It also records the details and calibration dates of the equipment used, who completed the check and when, and includes a traceability statement referencing NIST.

    PS Voltage Indication ( in VDC)

    DMM Measurement ( in VDC)

    Lower Tolerance ( in VDC)

    Upper Tolerance ( in VDC)

    As Found

    • Pass
    • Flag
    • Fail

    As Left

    • Pass
    • Flag
    • Fail

    Enter the desc, MFR, Model, S/N, and Cal dates below

    Verification Completed by:

    Date Completed:

    ECCO Technicians make Pass/Fail Statements of compliance by comparing the verification data against the tolerance(s) without factoring in the measurement uncertainty. Reference of Traceability The critical instruments used for this verification are traceable to the National Institute of Standards and Technology (NIST) through certification documents on file at ECCO. Verification is performed in compliance with MIL STD 45662A. A critical instrument is any equipment that requires verification.

Source: ECCO Safety Group - Boise (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.