Hoshizaki Ice Machine KM-1100MAH, MWH, MRH KM-1340MAH, MWH, MRH KM-1601MRH/3: Cleaning and Sanitizing Checklist Hoshizaki Ice Machine KM-1100MAH, MWH, MRH KM-1340MAH, MWH, MRH KM-1601MRH/3: Cleaning and Sanitizing Checklist The ice maker must be cleaned & sanitized at least once a year.
Cleaning Prep: 1. Remove the Front Panel, move the control switch to OFF. After 3 min., move the switch to ICE, then replace the panel. 2. After 3 min., remove the Front Panel, move the switch to OFF. 3. Remove all ice from the ice storage bin and/or dispenser. 4. Remove the Front Insulation Panel, slide the Cube Guide to right. Remove the Rubber Cap & Sleeve covering the Overflow Pipe. Unscrew the Overflow Pipe. Once the water tank has drained, replace all the items. 5. Refill water tank by moving the control switch to ICE, replace the Front Panel. After 3 minutes, remove the Front Panel, then move the control switch to OFF. 6. Remove the Front Insulation Panel. Pour 14 fl.oz (414 ml) of Hoshizaki Scale Away into the water tank. Replace the Front Insulation Panel. Turn the cleaning valve left until completely vertical (open). 7. Move the control switch to WASH, replace Front Panel. 8. After 30 minutes, remove Front Panel, then move the control switch to OFF.
NOTICE! DO NOT leave the control switch on WASH for extended periods when water tank is empty. It will damage water pump seals. 9. Remove the Front Insulation Panel, slide the Cube Guide to right. Remove the Rubber Cap & Sleeve covering the Overflow Pipe. Unscrew the Overflow Pipe. Clean all items (See Step 10). Once the water tank has drained, replace all the items. 10. In bad water conditions, a more thorough cleaning may be required. Turn off power supply, clean all items in a solution of 5 oz. of Scale Away per gallon of warm water. Rinse and replace the cube guides, float switch,
water supply tubes, spray tubes and spray guides. Turn
on power supply. Otherwise, continue to Step ༘.
RINSE 1 (19): (Steps 19-21)
RINSE 1 (20): (Steps 19-21)
RINSE 1 (21): (Steps 19-21)
RINSE 2 & 3 (22): (Steps 22-28)
Source: MaintainX (Community Member)
Please note that any procedure, checklist, or other document available in the MaintainX Global Procedure Library is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.