Back

Excavator Inspection

Case Construction Customized Maintenance Inscpetion Checklist. A routine inspection is designed to help prevent potential safety issues that could be caused by malfunctioning or damaged equipment.
MaintainX
07/13/2022

Excavator Inspection

103 steps
Case Construction Customized Maintenance Inscpetion Checklist. A routine inspection is designed to help prevent potential safety issues that could be caused by malfunctioning or damaged equipment.
  • W.O. #

  • Date

  • Model

  • Technician Signature

    Click here to sign
  • P.I.N.

  • Hours

  • Customer Name

  • Address

  • City, State, Zip

  • Phone

  • Customer Signature

    Click here to sign
  • Item #

  • Comments

  • Safety Equipment/Operator Cab

  • Safety Decals

  • Operators Manual

  • Seat Belts

  • Cab Mounts

  • Controls/Safety Lever Switch

  • Wipers

  • Defrost/Heat/A/C Fan

  • Lights

  • All Instruments

  • Cab Filters

  • Horn

  • Travel Movement Alarm Function

  • ROPS

  • ID Tag Present

  • Check Operation & Function of SiteWatch™ Equipment

  • Check Operation & Function of Machine Control Components

  • Engine

  • Belts/Tensioner

  • Exhaust Smoke

  • Unusual Noise

  • Turbocharger

  • Intake System

  • Muffler/Exhaust System

  • Fuel Pumps

  • Fuel Lines/Clamps

  • Fuel Shut-Off System

  • Fuel Leaks

  • Fuel Injectors, Click/Cut-Out Test

  • Fuel Tank, Cap, Vent & Sediment Drain

  • Engine Fuel Filters

  • Engine Throttle Function

  • Engine Oil/Filter

  • Oil Leaks

  • Engine Air Filters

  • Engine Valve Adjustment

  • Tier 4 CEOR

  • Exhaust Pipes to DPD Chamber

  • Operation, Complete Manual/Forced Regeneration

  • Electrical Connectors

  • DPD Chamber for Damage or Cracks

  • Pressure Differential Hoses, Cracks & Clamps

  • Temperature & Pressure Sensor Wires, Routing & Clamps

  • Cooling System

  • Radiator Core

  • Fan Assembly

  • Hoses/Clamps/Cap

  • Water Pump

  • Coolant Level

  • Coolant Leaks

  • Fluids/Lubrication

  • Lubricate Grease Points

  • Swing Gear

  • Swing Gearbox Oil

  • Final Drives

  • Breathers

  • Swing Gearbox Lower Bearing Lubricate

  • Hydraulic

  • Lines/Hoses

  • Control/Linkage

  • Oil Cooler

  • Cylinder/Valves

  • Reservoir

  • Operational

  • Cycle Times

  • Hydraulic Oil

  • Hydraulic Oil/Filters

  • Hydraulic Fluid Particle Count Analysis

  • Electrical

  • Connections

  • Battery Hold-Down

  • Starter

  • Alternator

  • Master Disconnect Switch

  • Fault Codes, Check/Record/Erase (Repair Actions May Be Required)

  • Powertrain

  • Linkage/Controls

  • Operational

  • Travel Motors Speed/Tracking

  • Undercarriage

  • Track Condition

  • Rollers

  • Idlers

  • Sprockets

  • Track Shoes/Bolts

  • Pins/Bushings

  • Track Adjustment

  • Rock Guards

  • Miscellaneous

  • Bucket Teeth/Cutting Edge

  • Dipper, Boom & Bucket Pins & Bushings

  • Ground-Engaging Tools

  • Welds/Frames

  • Sheet Metal

  • Swing Lock/Brake

  • Additional Maintenance

  • Others

  • Others

  • Others

  • Others

  • Others

Source: MaintainX (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Global Procedure Library is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.