AT24-06 Monthly Calibration

This procedure confirms that machine power supplies meet specified voltage tolerances. Using a calibrated meter, readings are measured and recorded to ensure equipment operates correctly and safely.
TAC Manufacturing
12/10/2025

AT24-06 Monthly Calibration

    Calibration Procedure

    40. Measure the voltage at the 24.00vdc power supply. (23.8vdc - 24.2vdc)

    • at24-0540.PNG
    Meter name
    Unit

    50. Measure the voltage at the 12.00vdc power supply. (11.8vdc - 12.2vdc)

    • at24-0550.PNG
    Meter name
    Unit

    60. Measure the voltage at the 5.00vdc power supply. (4.8vdc - 5.4vdc)

    • at24-0560.PNG
    Meter name
    Unit

    70. Inside the enclosure measure the voltage between the GND connection and positive 12vdc power connection. (11.7vdc - 12.2vdc)

    • at24-0570.PNG
    Meter name
    Unit

    80. Measure the voltage between the GND connection and positive +5vdc power connection. (4.8vdc - 5.3vdc)

    • at24-0580.PNG
    Meter name
    Unit

    90. Measure the voltage between the GND connection and positive 6.2vdc power connection. (5.8vdc - 6.5vdc)

    • at24-0590.PNG
    Meter name
    Unit

    140. Enter the ID# of the voltage meter that was used.

    150. Sign Off

    Click here to sign

Source: TAC Manufacturing (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.