This procedure is used to shut down each lift at the end of the winter season so equipment is protected, pests are kept out, and the lift is ready for the next operating season.
Crotched - Lifts
03/28/2026

Winter Shutdown Procedure

This procedure outlines the end-of-winter shutdown of a ski lift, covering the drive terminal mechanical and electrical systems, engine fuel, general cleaning of both terminals and the lift shack, and the return terminal. It guides the technician through greasing, fluid checks, fuel handling by engine type, heater shutdown, rodent prevention, cleanup, inventory, a final lift inspection, and a grease sample from the bullwheel.

    Drive Terminal Mechanical

    Gas or Diesel EVAC

    if the answer is "oneOf [Diesel ]"
    if the answer is "oneOf [Gas ]"

    Drive Terminal Electrical

    If heater can only be shut off via breaker, isolate power and disconnect heater completely. Make new work order to fix this condition

    (LV ONLY, 480V PANELS MUST STAY CLOSED)

    Replace covers, vacuum mouse droppings, remove anything that is not wiring.

    General Both Terminals

    Special attention to any food items

    All dirty rags to shop. Clean up any grease/oil. Remove extra consumables (if there are 5 cans of brake cleaner, leave 1 take 4 back to shop). Organize tools, any tools that should live at the shop should go back to the shop. Organize parts, any parts that are Lift specific can stay at that lift, shared parts should go back to the shop. Parts in terminals should be inventoried.

    Police area around terminal, lift shack and under lift shacks/decks. Any garbage should be thrown out

    Return Terminal

    Clean area where grease purges very well, once grease purges, collect sample in clean container and label. We will give these samples a basic "analysis"

    Final

    Notes

    Lift Hours

    Meter name
    Unit
Source: Crotched - Lifts (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.