A - Fixed Annual Electrical
This procedure outlines the steps for conducting an annual electrical maintenance inspection for a lift, ensuring all components and systems are functioning correctly and meet safety standards.
A - Fixed Annual Electrical
This procedure outlines the steps for conducting an annual electrical maintenance inspection for a lift, ensuring all components and systems are functioning correctly and meet safety standards.
Pre-Maintenance Preparation
Ensure understanding of potential hazards before starting maintenance.
Ensure all energy sources are properly locked out and tagged out.
Verify that all safety guards are in place and functional.
AC Inspection
Inspect all AC components
Are all heaters functioning?
Battery Maintenance
Are all chargers functioning?
Brake Pump Motor
Follow manufacturer’s recommendations for brake pump motor maintenance
Document any specific actions taken.
Safety Related Control Functions Test
Test emergency and safety functions
Control Functions Test
Test control functions
Electronic Speed-Regulated Drive Monitoring Test
Test drive monitoring functions
Low Voltage Control Circuit Inspection
Programmable Logic Controllers (PLC)
Motor Control Inspection
Follow manufacturer’s maintenance recommendations for motor control
Document any specific actions taken.
Motor/Prime Mover Inspection
Measure resistance between armature and ground
Record values using a 500V MEG-Ohm meter.
Measure resistance between armature and field
Record values using a 500V MEG-Ohm meter.
Measure resistance between field and ground
Record values using a 500V MEG-Ohm meter.
Measure and record brush lengths
Smoke Alarm Inspection
Test smoke alarms
Replace smoke alarms if not functional
Tower Circuit/Communication Line Inspection
Acknowledge completion of all inspections
Sign with both first and last name to confirm all inspections meet applicable standards.
Click here to sign
Source: Lift Maintenance Sandbox - Vail Resorts (Community Member)