This procedure outlines the steps for conducting an annual electrical maintenance inspection for fixed grip systems. It includes pre-maintenance preparations, detailed inspections of various electrical components, and tests for safety and control functions. The procedure ensures compliance with manufacturer recommendations and applicable standards.
A - Annual Electrical Fixed
This procedure outlines the steps for conducting an annual electrical maintenance inspection for fixed grip systems. It includes pre-maintenance preparations, detailed inspections of various electrical components, and tests for safety and control functions. The procedure ensures compliance with manufacturer recommendations and applicable standards.
Pre-Maintenance Preparation
AC Inspection
Inspect all AC components
Verify all heaters are functioning
Battery Maintenance
Verify chargers are functioning
Brake Pump Motor
Follow manufacturer’s recommendations for brake pump motor maintenance
Safety Related Control Functions Test
Test safety related control functions
Control Functions Test
Test control functions
Electronic Speed-Regulated Drive Monitoring Test
Conduct drive monitoring tests
Low Voltage Control Circuit Inspection
Inspect low voltage control circuit components
Programmable Logic Controllers (PLC)
Verify adequate supply of spare parts
Motor Control Inspection
Follow manufacturer’s maintenance recommendations for motor control
Motor/Prime Mover Inspection
Measure resistance between armature and ground
Measure resistance between armature and field
Measure resistance between field and ground
Measure and record brush lengths
Smoke Alarm Inspection
Replace smoke alarms if not functional
Tower Circuit/Communication Line Inspection
Inspect tower circuit and communication line components
Acknowledge completion of all inspections