This is a procedure that involves conducting a physical inspection and assessment of the equipment to evaluate their reliability and performance. The process identifies potential issues, ensures optimal functioning, and helps in planning for preventative maintenance or necessary repairs.
24P DC Columbus - Cintas
01/29/2025

OEX - Reliability Physical

This is a procedure that involves conducting a physical inspection and assessment of the equipment to evaluate their reliability and performance. The process identifies potential issues, ensures optimal functioning, and helps in planning for preventative maintenance or necessary repairs.
Procedure Max Score: 424

    *** LOTO Confirmation Statement - DO NOT EDIT/REMOVE ***

    All hazardous energy has been isolated using LOTO procedures?

    All potential stored or residual energy has been relieved, disconnected, restrained, lowered, and/or otherwise rendered safe?

    Summary

    Date

    Group

    Location Number & Name

    Group Vice President

    General Manager

    Production Manager

    Maintenance Supervisor

    Corporate Engineer

    Regional Health & Safety Co-ordinator

    03 CMMS

    Perform a spot check of 5 parts that are entered into inventory, 3 must be accurate. Parts are being charged out in MaintainX, as verified by WOs.

    • Pass
    • Flag
    • Fail

    Critical spare parts being essential to a reliable location. A spot check of 3 random critical spare parts is conducted using inventory and storage location. Critical spare parts are dictated by the location and approved by the Corporate Engineer.

    • Pass
    • Flag
    • Fail

    Parts organized per the REVISED MaintainX Parts Storage Standardization training PowerPoint

    • Pass
    • Flag
    • Fail

    05 Powered Industrial Trucks and Lifts

    Verify proper operation and integrity of forklift/electric pallet jack. Proper operation examples would be up/down lifting, side to side fork shifting, tilt of forks, horn works, lights work, seat not damaged, seat belt is in good working order and intact, keys are not left in the forklift, there are no hydraulic leaks, and operators can demonstrate good working brakes. For a comprehensive list of operational checks, engineers and plant partners should refer to the manufacturer's manual and preventive main

    • Pass
    • Flag
    • Fail

    Verify proper operation and integrity of man lift/scissor lift. Proper operation examples would be up/down lifting, horn works, and if stabilizing stanchions were designed to be used with the lift - that they are present and intact. Also that keys are not left in the lift, there are no fluid leaks, and operators can demonstrate good working brakes or stop controls. For a comprehensive list of operational checks, engineers and plant partners should refer to the manufacturer's manual and preventive maintenan

    • Pass
    • Flag
    • Fail

    07 Facility Review

    Housekeeping / Lint Control

    Bathrooms - inspected and in working order, paint, wallpaper, tile, ceiling tiles, partitions, fixtures, in good working order.

    • Pass
    • Flag
    • Fail

    Lunchroom - Inspected, floors clean, cabinet integrity, refrigerator, paint, wallpaper, ceiling tiles, fixtures is in working order. Refrigerator is in working condition and at acceptable temperature levels of between 35°F and 46°F. The ice machine must be in good working order and have no water leaks.

    • Pass
    • Flag
    • Fail

    Security / Lighting

    Verify proper operation and integrity of automatic lint blowdown fans and portable fan. Ensure fixed fans are tied into the fire alarm system, and not in bypass. Maintenance partner must be the only one setting up and operate portable fan.

    • Pass
    • Flag
    • Fail

    Office lighting inspected for integrity (this line focuses on fixture integrity / wiring and while some individual light bulbs may be out - do not deduct points unless there is no documented plan for regular inspection of these fixtures and replacement of extinguished bulbs). Proof of inspections documented in MaintainX.

    • Pass
    • Flag
    • Fail

    Exterior lighting inspected monthly and operational. Proof of inspections documented in MaintainX.

    • Pass
    • Flag
    • Fail

    Timers and photo cells for exterior lighting set properly.

    • Pass
    • Flag
    • Fail

    Plant lighting inspected for integrity. (this line focuses on fixture integrity / wiring and while some individual light bulbs may be out - do not deduct points unless there is no documented plan for regular inspection of these fixtures and replacement of extinguished bulbs). Proof of inspections documented in MaintainX. Unused fixtures should be taken down in a safe manner.

    • Pass
    • Flag
    • Fail

    Facility Integrity

    Office and Restrooms - Inspected, paint, wallpaper, ceiling tiles, cubicles, fixtures, and fixtures good working order.

    • Pass
    • Flag
    • Fail

    Personnel doors and roll up doors operational and inspected for integrity. On any motorized operators, check to ensure required safety stop is present and functional.

    • Pass
    • Flag
    • Fail

    Dock levelers inspected for proper operation and integrity. Pinch points properly labeled for visual caution awareness. (examples include yellow paint, safety warning floor tape, confined space labels, etc.…) Powered dock levelers must have interlocks to prevent operation when overhead door is closed.

    • Pass
    • Flag
    • Fail

    Floors inspected for proper and acceptable integrity. This is not intended to cause a reduction in points for normal wear or a few spots where floor paint or epoxy may be chipped or not present. While very difficult to quantify every possible floor scenario that would result in receiving or not receiving Assessment points, generally - items that would result in points lost are as follows: any chipped concrete hole more than 2" in diameter and 1/2" in depth (these should be patched - patching is accepted

    • Pass
    • Flag
    • Fail

    Outside storage containers / shelter areas inspected for integrity. Ensure that these are secured to ground appropriately if required, that they are not rusting, and that the roof is intact and has no holes/leaks.

    • Pass
    • Flag
    • Fail

    Parking Lot / Grounds Upkeep / Storm Water Pollution Prevention

    Parking lot inspected for integrity - No potholes greater than 1' Diameter and 3" deep; No broken, loose or missing pavement and no "Alligator" cracks greater than 1/2" Wide. Parking areas are properly marked. If evidence is present of active and appropriate repairs (Cold patch, Seal coat, Crack Seal) being made then don't deduct points.

    • Pass
    • Flag
    • Fail

    Parking lots shall be seal coated and crack sealed and striped a minimum of every 5 years or more frequently as environmental conditions warrant, and as agreed upon by Engineering and Location.

    • Pass
    • Flag
    • Fail

    Exterior lot is organized and free of debris

    • Pass
    • Flag
    • Fail

    No improper storage of waste materials, chemicals, ink towels, Safe washers or soiled goods in outside areas that could result in storm water pollution. Outside sludge container shall not be leaking.

    • Pass
    • Flag
    • Fail

    08 Roof & Associated Equipment

    Ventilation Fans & Exhaust / Stack Integrity

    All ventilation fans and exhaust stacks are intact, in working order and inspected for missing covers, parts, exposed wiring, missing bird guards, and other designed components.

    • Pass
    • Flag
    • Fail

    If applicable, all drive through exhaust ducts must be intact and in working order as per original design. If these devices are not in use when trucks are inside the building, then no points shall be given the same as if the system is not operational.

    • Pass
    • Flag
    • Fail

    Roof Lint Accumulation

    No excessive lint accumulation on the roof and there is evidence of regular maintenance and removal if there is an issue causing lint to escape the dryer and steam tunnel lint screens. If there is lint present at these roof penetrations it should be cleaned regularly and should not exceed an area of 54" in diameter or 3/8" thick. For locations that have a ballasted roof - the lint shall not completely cover all the paver ballast stones over an area in excess of 36".

    • Pass
    • Flag
    • Fail

    Roof Integrity

    Roof drains, gutters & scuppers are clear of leaks, debris & blockages.

    • Pass
    • Flag
    • Fail

    Roof inspected for integrity. All leaks, splits, and punctures have been addressed. Roof caution perimeter line 6' from edge is visible and in good condition. Roof access hatch, ladder and guard/hand rail are in good condition and working order.

    • Pass
    • Flag
    • Fail

    09 HVAC Systems

    Check that thermostats are in place, functional and programmed for efficiency

    • Pass
    • Flag
    • Fail

    HVAC units shall be properly maintained on a semi-annual basis on all RTU's. Determine simply if the unit is outputting heated or cooled air as called for by the HVAC controls, including the thermostat. If any units are not working then these points are deducted.

    • Pass
    • Flag
    • Fail

    Gas/Electric heaters should be clean and in good operating condition. Gas supplies feeding "pilot" lights on these units shall be isolated during the non-heating seasons.

    • Pass
    • Flag
    • Fail

    10 Compressed Air Systems

    Inspect machine integrity of compressor.

    • Pass
    • Flag
    • Fail

    Air receiver tank properly secured. Ensure the receiver pressure gauge is functioning. Ensure the pressure relief valve on all receiver tanks are in place.

    • Pass
    • Flag
    • Fail

    Ensure all automatic blow down devices are in place and operational. These must be plumbed to an appropriate drain for self containment (Cintas pit or floor drain- not storm water).

    • Pass
    • Flag
    • Fail

    Check air filters and pre-filters to ensure they are clean and show evidence of being changed regularly. Use PM work orders as a resource.

    • Pass
    • Flag
    • Fail

    State or local permit up to date and posted for receiver tank (N/A if not required )

    • Pass
    • Flag
    • Fail

    Air dryer working properly. Air system checked for moisture at a minimum of two locations in the plant at air trap inspection bowls. If these trap bowls are greater than 1/4 full, this indicates a trouble issue.

    • Pass
    • Flag
    • Fail

    11 Boiler / Steam System

    Low water cutoff daily checks shall be documented using boiler low water cutoff Hartford Steam Boiler tag system or insurance equivalent form. All previous months logs must be kept on file for a minimum of 1 year unless otherwise required to be in compliance with local/state regulations.

    • Pass
    • Flag
    • Fail

    Corporate Engineer must witness a bottom blowdown, with the boiler feedwater pumps off, activating primary and secondary low water cutoffs to ensure proper operation. Depending on boiler style and local regulations, boiler may only have a single primary low water cutoff - check with boiler rep and/or local regulations.

    • Pass
    • Flag
    • Fail

    Low water and flame safety alarms are functional and an audible or visual alarm is installed outside of the boiler room or in the Wash Alley. The intent of this item is to standardize a critical item of warning be established outside of the boiler room itself so that Cintas location partners can hear and/or see this alarm and quickly notify their maintenance team or supervisors. As long as the alarm can be seen and/or heard in an area where partners are present more than 80% of the time a location is runni

    • Pass
    • Flag
    • Fail

    Boiler inspection/operation certificate must be current and displayed in the boiler room as required by local or state regulations. Previous years certificates shall be kept on file as required by local/state regulations.

    • Pass
    • Flag
    • Fail

    A Corporate Engineer approved sample cooler online and functional so boiler water sample does not exceed 120° F.

    • Pass
    • Flag
    • Fail

    Ensure that the boiler room make up air supply exists and that the air flow is not impeded.

    • Pass
    • Flag
    • Fail

    Inspect boiler level sight glass as required by Cintas (see link) and burner flame inspection viewport is present and checked for integrity. No leaks or cracks should be present and flame should be clearly visible through the viewport. Flame should have some blue tips in appearance, when in high fire.

    • Pass
    • Flag
    • Fail

    Burner linkage is intact and has no excessive free play. Witness marks are visible for reference on all adjustment points. See link for proper marking paint to use (No Sharpies or Markers).

    • Pass
    • Flag
    • Fail

    All hand valves function properly (blow down, sample, low water test).

    • Pass
    • Flag
    • Fail

    Boiler room must be neat clean and organized. The boiler room shall not be used for storage of combustibles and flammables.

    • Pass
    • Flag
    • Fail

    Boiler room steam line insulation inspected for integrity

    • Pass
    • Flag
    • Fail

    Inspect electrical system integrity (push buttons, conduit, indicators lights, positional switches, check for any loose or exposed wiring)

    • Pass
    • Flag
    • Fail

    Ensure boiler automatic surface blowdown, with conductivity controller, is in place and operating properly as confirmed by location boiler chemical representative outside contractor and when compared to the Conductivity reading on the Boiler Log.

    • Pass
    • Flag
    • Fail

    Boiler door & associated hardware integrity.

    • Pass
    • Flag
    • Fail

    System inspected for steam, water and gas leaks to ensure none exist.

    • Pass
    • Flag
    • Fail

    Inspect boiler feed water tank sight glass for integrity. No leaks or cracks should be present. Inspect the level control system for proper operation (calls for water, valve opens, valve shuts). No manually throttled valves being used as level control.

    • Pass
    • Flag
    • Fail

    Polishing softener online, functional and tested to output 0 ppm of hardness

    • Pass
    • Flag
    • Fail

    Inspect Feed Water system integrity to ensure both pumps are operational and that only one is online at a time. Must have a pressure gauge installed and operational prior to the stainless steel spring check valve of each feed water pump. Ensure boiler feed water line has a functioning stainless steel spring check valve at the boiler.

    • Pass
    • Flag
    • Fail

    Ensure feed water tank is insulated and intact. Feedwater temperature shall be 180°-200°F. Removable jacket insulation is preferred.

    • Pass
    • Flag
    • Fail

    Electrical integrity and all panel indicator lights are properly labeled and functioning properly.

    • Pass
    • Flag
    • Fail

    12 Water System

    Hot water delivery temperature at 140°F to 155°F. Inspect maintenance daily checklist for proper water temperature over time.

    • Pass
    • Flag
    • Fail

    Water Pressure for Hot, Tempered or Cold delivery supply headers (30-60 psig).

    • Pass
    • Flag
    • Fail

    Water levels checked and verified (+/- 6") to water system PC / HMI for pits and tanks (N/A if PC not available).

    • Pass
    • Flag
    • Fail

    Water pumps inspected for integrity.

    • Pass
    • Flag
    • Fail

    Electrical integrity and all panel indicator lights are properly labeled and functioning properly on all water system components.

    • Pass
    • Flag
    • Fail

    Water tank insulation and covering inspected for integrity

    • Pass
    • Flag
    • Fail

    Water softener system inspected for integrity. N/A if no water softener.

    • Pass
    • Flag
    • Fail

    Check hardness with test kits while on site. Plant water with softener shall be 0 to 2 grains max. Plant water without softener shall be less than 4 grains (1 grain = 17ppm)

    • Pass
    • Flag
    • Fail

    Check integrity of Spence Valve Temperature control (or comparable) for proper operation and control.

    • Pass
    • Flag
    • Fail

    Water system inspected for leaks (tanks, piping, valves, automatic fill control valves)

    • Pass
    • Flag
    • Fail

    Emergency bypasses (Hot & Temp water fill valves, Kunkle pressure relief valve, Stack Economizer by pass, Heat reclaimer bypass, Tempered water cool down valve, hot water header return line, Steam heater control bypass) must be in the proper operating position

    • Pass
    • Flag
    • Fail

    The Kemco Motor and Pump Lifting System or equivalent must be installed in accordance with the safety bulletin. Alternative method must be approved by Corporate Engineer & Engineering Director.

    • Pass
    • Flag
    • Fail

    Inspect integrity of heat reclaimer for external leaks and ensure back flush valve is operating properly

    • Pass
    • Flag
    • Fail

    Vent Condenser inspected for integrity and proper operation. (N/A if location is not equipped with one)

    • Pass
    • Flag
    • Fail

    Ensure all temperature and pressure indicators and gauges in the system are in place and operating properly. - Stack Economizer Pressure Indicator must be within 5-10 PSI when filling HW tank, 0 when not filling, never negative.

    • Pass
    • Flag
    • Fail

    Stack economizer is providing a rise in hot water temp prior to steam heat exchanger. (N/A if no stack economizer in place)

    • Pass
    • Flag
    • Fail

    DCHW

    Inspect DCWH for integrity and proper operation. (N/A if location is not equipped with one)

    • Pass
    • Flag
    • Fail

    Electrical integrity and all panel indicator lights are properly labeled and functioning properly.

    • Pass
    • Flag
    • Fail

    Burner linkage is intact and has no excessive free play. Witness marks are visible for reference on all adjustment points. See link for proper marking paint to use (No Sharpies or Markers).

    • Pass
    • Flag
    • Fail

    Tempered water delivery temperature at 70° to 100°F. Inspect maintenance daily checklist for proper water temperature over time. Without waste water heat recovery, N/A.

    • Pass
    • Flag
    • Fail

    13 Waste Water System

    Sludge System Integrity

    Ensure that pit screens and wash alley trench screens (if applicable) are cleaned regularly. (For normal operating plants these shall be cleaned at a minimum of once per shift.)

    • Pass
    • Flag
    • Fail

    Inspect filter press for proper operation and filter cake consistency. Ensure the following issues are not occurring: sludge blowouts, air leaks, water leaks. Ensure proper integrity of hydraulic system. Ensure the proper integrity of the filter cloths.

    • Pass
    • Flag
    • Fail

    Electrical integrity and all panel indicator lights are properly labeled and functioning properly.

    • Pass
    • Flag
    • Fail

    Check levels of sludge in WW pits using safe methods. Maximum acceptable sludge level is 3 feet from the bottom of pit. At a minimum, pits & trenches must be cleaned annually.

    • Pass
    • Flag
    • Fail

    Inspect integrity of waste water pit decking to ensure no excessive corrosion or damaged decking supports.

    • Pass
    • Flag
    • Fail

    Integrity and Logs

    Inspect shaker screen for integrity and proper operation. Proper operation can be witnessed in the following points: that the elliptical nature of the shaker rotation is intact and causing the larger particles to be rotated around on top of the screen and out the discharge chute; that the screen is not blinded and that excessive water carryover is not entering the shaker sludge discharge.

    • Pass
    • Flag
    • Fail

    Electrical integrity and all panel indicator lights are properly labeled and functioning properly on all water system components. Verify that all system pressure gauges are working, and where applicable, agree with corresponding pressure displayed on control panel.

    • Pass
    • Flag
    • Fail

    pH probes are cleaned and calibrated at least weekly (NA if pH probes are not in place).

    • Pass
    • Flag
    • Fail

    If an air flotation system is used, verify recirculation pump pressure is within appropriate range (80 to 120 psi or to manufacturer's specifications). (N/A if DAF is not in place)

    • Pass
    • Flag
    • Fail

    Check for proper operation and system integrity of the following WW components: Chemical pumps, transfer pumps, mixers, gauges, skimmer, EQ Blower, EQ Tank, TSS/Turbidity meter, pit mixer or blowers (as Applicable)

    • Pass
    • Flag
    • Fail

    Verify that excessive carryover is not present through observation and review of logs. Every plant with wastewater treatment should work with Wastewater chemical vendor to establish benchmark for location to meet compliance established by permit and cost control measures. If no benchmark established then benchmark of >10 of 21 on turbidity wedge

    • Pass
    • Flag
    • Fail

    Reports / Operating Procedures

    Permit dictated sampling point is inspected and cleaned as necessary. At a minimum, this point must be cleaned (water jetting) at a minimum of annually. SAFETY NOTE: Cintas partners shall not enter this confined space.

    • Pass
    • Flag
    • Fail

    CMF

    Inspect centrifuge for proper operation. No free liquids should be present with solids in roll-off containers. All guards on centrifuge should be in place.

    • Pass
    • Flag
    • Fail

    All system pumps inspected for integrity. Verify that Feed and Circulation pumps are operating at the correct pressure (Feed Pump: 40-60 psi, Circulation Pump: 65-85 psi). (N/A if CMF is not in place)

    • Pass
    • Flag
    • Fail

    All panel Indicator lights are functioning properly and labeled. Inspect electrical components for system integrity.

    • Pass
    • Flag
    • Fail

    Verify that the system is being properly cleaned. Proper cleaning consists of: Wastewater and Feed tanks emptied daily, ceramics cleaned daily using Norchem standard cleaning product or a high pH clean, supplement cleans performed at minimum on a bi-weekly basis using high and low pH cleans, and any solids removed from Wastewater tanks monthly or more often as needed. If pits are used in place of tanks, verify location is managing sludge level.

    • Pass
    • Flag
    • Fail

    Water Reuse?

      Treatment System

      Ensure Water Reuse pumps are inspected for proper operation and integrity (seal leakage).

      • Pass
      • Flag
      • Fail

      If using water treatment system with Reuse, where applicable ensure turbidity meter is installed and functioning properly (validate with visual inspection and turbidity wedge).

      • Pass
      • Flag
      • Fail

      All panel Indicator lights are functioning properly and labeled. Inspect electrical components for system integrity.

      • Pass
      • Flag
      • Fail

      Water system inspected for leaks (tanks, piping, valves, automatic fill control valves).

      • Pass
      • Flag
      • Fail

      14 Sling Storage Rail System (Dirty and Clean)

      Inspect 5 random dirty (and 5 random clean if applicable) sling bags for damage to cords, eyelets, sling lifting loops, and the bag itself. Ensure that these components are in tact and operating as designed.

      • Pass
      • Flag
      • Fail

      Inspect 5 random soil system sling trollies for damage to wheels, wheel bearings, sling bag release string spring hook integrity and structural steel integrity. Ensure a documented service plan is in place in MaintainX.

      • Pass
      • Flag
      • Fail

      Inspect wire rope cables or chain for integrity and proper installation

      • Pass
      • Flag
      • Fail

      Ensure that system switches/air cylinders/brushes/photo sensors/stops/gates of, all re-elevation lifts, washer buffers, dump station and all other rail components are working properly and intact and no air leaks are present. Soil system issue tracking map must be in place and utilized to correct issues.

      • Pass
      • Flag
      • Fail

      Inspect scales, lifts and hoists for mechanical/electrical integrity and proper operation. If a Ryco or similar type lift system is in place, then annual inspection by qualified outside contractor performed within the past 12 months and on file. All applicable items have been implemented, a written action plan, and applicable work order is in place. The written action plan needs to be approved by the GM. Approved soiled sling load weights do not exceed the lowest weight between OEM & overall rated system

      • Pass
      • Flag
      • Fail

      Sling bag fall protection fencing / system is inspected for integrity and ensure that it covers all applicable areas to prevent bags/product from falling on partners. Fall protection wire mesh shall be in place with no gaps; shall be affixed with metal ties to the fall protection piping system as required by the installer (check with installer if not known); no pipes shall be loose or bent; repairs must be made (when required) within three business days; the wire mesh must be ON TOP OF THE PIPING SUPPORT S

      • Pass
      • Flag
      • Fail

      15 Wash Alley Washers

      Safety-Verify all OEM guards and shrouds in place (varies by manufacturer), check all audible and/or visual alarms (if designed into original machines), and proper warning signage and ensure it is in place and operational (unless approved exception by safety due to manufacturer not having system for alarms). Examples of this are the washer tilt alarms, confined space labels and tilt/pinch signage that was installed by the manufacturer or by Cintas.

      • Pass
      • Flag
      • Fail

      Check door assembly overall integrity (locks, seal, glass, alignment, excessive speed of opening or closing, proper operation). Inner door locks, brass guides, Teflon strips, outer door seal, and catch pan, outer door chains

      • Pass
      • Flag
      • Fail

      Inspect the drive train (Motor, Gear box, bearing, seals, shaft, and auto lubers). Listen for motor bearing failures and assess shaft is properly aligned. Inspect Bearings (listen for inappropriate noise). Inspect Seals; If a seal leak was present and stopped, the location must open a corrective work order, seal must be inspected for 4 consecutive weekly checks with no sign of leakage prior to closing out work order. All seal leaks must be repaired within 90 Days of being identified.

      • Pass
      • Flag
      • Fail

      Inspect belts to ensure all are present and tensioned properly

      • Pass
      • Flag
      • Fail

      Inspect Braking system and ensure Machine stops as designed from High Speed Extract. Inspect that spotting pin activates properly on side load washers.

      • Pass
      • Flag
      • Fail

      Verify integrity of suspension system: check condition of grout, anchors, air bags, shocks, spring, shock tangs and associated hardware, and plates to ensure they are intact. Ensure cradle pins are retracting properly on side load washers. Ensure shocks are replaced annually.

      • Pass
      • Flag
      • Fail

      Shocks must be marked with date of change.

      • Pass
      • Flag
      • Fail

      Ensure tilting components are operational and working as designed (look at: tilt hinges, tilt cylinders, air bag, tilt stop, & tilt safety braces). These are critical safety items and therefore cannot have damaged components, missing locking pins or any other problem that prevents them from being installed on the washer hydraulic tilt cylinder.

      • Pass
      • Flag
      • Fail

      Inspect electrical system (labels, push buttons, pressure mats if installed, conduit, indicators lights, positional switches, and vibration switch in place and functional)

      • Pass
      • Flag
      • Fail

      Inspect chemical injection integrity. Connection to washer must be Stainless Steel.

      • Pass
      • Flag
      • Fail

      Water delivery system integrity - ensure there are no leaks in the system and that piping / valve integrity is not compromised by excessive corrosion. Ensure drains are not leaking and drain boots are in place.

      • Pass
      • Flag
      • Fail

      Hydraulic system integrity (Check for leaks, fluid levels, oil cooler integrity, filter change interval & ensure gauge and filter are intact). Ensure the hydraulic filter has a date of replacement placed on it and that no more than one year has passed since replacement. If filter is internal then proof of change must be verified by MaintainX WO.

      • Pass
      • Flag
      • Fail

      Pneumatic system integrity (Check system for leaks, ensure gauges are intact, check regulators and oiler for proper operation)

      • Pass
      • Flag
      • Fail

      Steam System integrity (Check for leaks (steam connections, hoses, etc.)) Ensure anti-whip cable is in place. Steam hose clamps should never be reused.

      • Pass
      • Flag
      • Fail

      Verify integrity of extractor or press diaphragm on a tunnel washer. (if not in place at location mark as N/A)

      • Pass
      • Flag
      • Fail

      Evidence of active preservation (painting / corrosion)

      • Pass
      • Flag
      • Fail

      Ex: of issues that would result in a loss of points: standing water around the washer; underside & trench area of the washer is excessively dirty so that it is difficult to see the paint on the washer frame or the color of the shocks underneath the washer (see photos of bad ex's); product should not be on top of the washers or inside the frame work of the washer where product has fallen out of sling bags; there should no buildup of lint/dust more than 1/4" on the washer or attached chute or frame.

      • Pass
      • Flag
      • Fail

      Inspect chute assembly for integrity and proper operation including water delivery. If a Braun Wash Alley, safety cables must be installed per Braun Washer Chutes Engineering Technical Bulletin.

      • Pass
      • Flag
      • Fail

      15 Wash Alley Dryers

      Safety-Verify all OEM guards and shrouds in place (varies by manufacturer), check all audible and visual alarms, and proper warning signage and ensure it is in place and operational. Examples of this are the dryer tilt alarms, confined space labels and tilt/pinch signage that was installed by the manufacturer or by Cintas.

      • Pass
      • Flag
      • Fail

      Dryer Drums - Check for plastic build up (<10%), no visible cracks in drum, check that drum spins "true" without excessive runout (see manufacturer specifications for drum specifications)

      • Pass
      • Flag
      • Fail

      Machine Foundation Intact - All anchor bolts in place and tight

      • Pass
      • Flag
      • Fail

      Door Integrity - Alignment of doors, seals in place and intact (rollers or door cables as applicable)

      • Pass
      • Flag
      • Fail

      Lint Collection – Functional, no damage to seals and screen, evidence of proper cleaning. Dryer duct cleaning inspections results shall be reviewed to ensure completion on the appropriate time schedule.

      • Pass
      • Flag
      • Fail

      Seals-Inspect drum brushes (internal wipers), felt or Teflon drum seals, gap ring seal for integrity

      • Pass
      • Flag
      • Fail

      Drive assembly integrity- Inspect condition of gearboxes, drive belts, drive motors, drive wheels, thrust rollers, shafts & bearings

      • Pass
      • Flag
      • Fail

      Temperature Probes and Gauges -Verify proper operation of all sensors by visual inspection of gauges or wash alley system master computer as necessary. No excessive lint build up on any probes.

      • Pass
      • Flag
      • Fail

      Tilting System - Inspect all components for integrity and proper operation, including pivot pins. Ensure tilt cylinder has no leaks and packings are free and clean of debris.

      • Pass
      • Flag
      • Fail

      Check pneumatic system integrity.

      • Pass
      • Flag
      • Fail

      Inspect electrical system integrity.

      • Pass
      • Flag
      • Fail

      Inspect mechanical integrity.

      • Pass
      • Flag
      • Fail

      General housekeeping in and around dryers

      • Pass
      • Flag
      • Fail

      Verify that Burner Maintenance is taking place (condition of burner, burner combs, air wings, flame rod, igniter, visual inspection of flame, combustion air blower and intake, visual inspection of gas train). Check gas system integrity.

      • Pass
      • Flag
      • Fail

      15 Wash Alley Shuttles

      Safety-Verify all OEM guards (All exposed rotating shafts covered) and shrouds in place and in good condition (varies by manufacturer), check all audible and visual alarms, and proper warning signage in place. Shuttle scanners and cameras are fully functional.

      • Pass
      • Flag
      • Fail

      No Significant Corrosion Issues - Inspect all structural pieces for corrosion

      • Pass
      • Flag
      • Fail

      Track - Fully anchored, end stops in place, smooth joints, and leveled properly with grout intact (if applicable).

      • Pass
      • Flag
      • Fail

      Drive assembly - Inspect condition of gearboxes, drive belts, drive motors, drive rollers, shafts & bearings

      • Pass
      • Flag
      • Fail

      Festoon - Rollers in place and in good repair, no cable splices, verify functionality of position switches. Festoon support stanchions and cable trolley track are in good working order.

      • Pass
      • Flag
      • Fail

      Belt - In overall good repair, alligator clips in place and complete, no major fraying greater than 10% of the original belt width and no major tears or holes greater than 4", proper alignment

      • Pass
      • Flag
      • Fail

      Electrical /Controls - Integrity of boxes, integrity of conduit (hard and flexible) to machine and motors or any other electrical parts, interlock controls, labels, control buttons in place and in good repair, check for any loose wiring

      • Pass
      • Flag
      • Fail

      Pneumatic system - Check system for leaks, check regulators and oiler for proper operation, check travel cylinder & brake (N/A if shuttle has no air system)

      • Pass
      • Flag
      • Fail

      General housekeeping in and around shuttle.

      • Pass
      • Flag
      • Fail

      15 Wash Alley Unload Conveyers

      Safety-Verify all OEM guards (All exposed rotating shafts covered) and shrouds in place and in good condition (varies by manufacturer), check all audible and visual alarms, and proper warning signage in place

      • Pass
      • Flag
      • Fail

      Belt - In overall good repair, alligator clips in place and complete, no major fraying greater than 10% of the original belt width and no major tears or holes greater than 4", proper alignment

      • Pass
      • Flag
      • Fail

      Drive assembly integrity- Inspect condition of gearboxes, drive motors, drive rollers, shafts & bearings

      • Pass
      • Flag
      • Fail

      Inspect electrical integrity & controls (labels, push buttons, indicators lights, photo switches, pendant or foot switch)

      • Pass
      • Flag
      • Fail

      General housekeeping in and around unload conveyor

      • Pass
      • Flag
      • Fail

      15 Wash Alley Chemical System

      Electrical /Controls - Integrity of boxes, integrity of conduit (hard and flexible), control buttons in place and in good repair, check for any loose wiring labeled properly.

      • Pass
      • Flag
      • Fail

      Verify no Air Leaks – Valves, piping, fittings and hoses

      • Pass
      • Flag
      • Fail

      Verify no chemicals Leaks – Valves, piping, fittings and hoses, pumps

      • Pass
      • Flag
      • Fail

      Verify no water Leaks – Valves, piping, fittings and hoses, pumps

      • Pass
      • Flag
      • Fail

      15 Wash Alley - WASS

      Washer, dryers and gate switches operational

      • Pass
      • Flag
      • Fail

      Shuttle switches and MED's operational intact and labeled

      • Pass
      • Flag
      • Fail

      All gates hinges and latches operational and fencing structural components intact

      • Pass
      • Flag
      • Fail

      Trap key sets in good working condition, LOTO key guarding in place and operable, and system being used per R-7014.

      • Pass
      • Flag
      • Fail

      Stack lights, audible alarms, and control panel lights are in good working condition

      • Pass
      • Flag
      • Fail

      15 Wash Alley (All Types including Tunnel Washers and Side Loaders)

      Red Zones are in place, in good condition, and applicable rules observed.

      • Pass
      • Flag
      • Fail

      15 Wash Alley (All Types including Tunnel Washers and Side Loaders) - Manual Wash Alley Dryer Lift

      Inspect hoist components (cables, chains, wire ropes, upper/lower limits, load hook safety catch) for integrity and proper installation

      • Pass
      • Flag
      • Fail

      Inspect hoist motor, gearbox for integrity and ensure that clutch/brake is operating properly ( With weight lifted bag remains in place)

      • Pass
      • Flag
      • Fail

      Operator Pendant on strain relief and inspected for integrity ( No exposed wires, buttons intact, housing intact, labeled)

      • Pass
      • Flag
      • Fail

      16 Shakeout

      PAMI/SAMI units inspected for integrity (check for lights, mirrors). Exemption from guarding on PAMI/SAMI stations that have been retrofitted with LED lighting.

      • Pass
      • Flag
      • Fail

      PAMI/SAMI Adjustability features in working order if applicable

      • Pass
      • Flag
      • Fail

      PAMI/SAMI Guards in place

      • Pass
      • Flag
      • Fail

      17 Press, Stockroom and Repair Area

      Inspect integrity of pressing equipment, to include, pads, covers, steam chests are clean and functional, steam, air/water, vacuum system, & controls. Verify all two hand controls.

      • Pass
      • Flag
      • Fail

      Inspect integrity of stockroom equipment, to include grading/repair/receiving work station tables, pinker, and barcode scanners.

      • Pass
      • Flag
      • Fail

      Automatic Emblem storage system operating properly, inspected for integrity, and checked for proper housekeeping. (N/A if none are in place)

      • Pass
      • Flag
      • Fail

      Inspect heat seal machine integrity, to include Teflon & pads are in good condition, no air leaks, regulator set to a minimum of 70 psi, guarding is in place, and properly anchored to the work station. Ensure top platen only goes down when aligned over bottom platen. Verify two hand controls.

      • Pass
      • Flag
      • Fail

      18 Steam Tunnel

      Autoloader functioning properly (N/A if none are in place).

      • Pass
      • Flag
      • Fail

      Conveyor motor speed control in working order. Inspect gearbox integrity.

      • Pass
      • Flag
      • Fail

      Ensure that burner shuts off when conveyor stops moving, per technical safety bulletins.

      • Pass
      • Flag
      • Fail

      Tube not excessively worn, chain is moving smoothly with minimal bent/missing pendants, minimal garments fall off conveyor and required guards are in place.

      • Pass
      • Flag
      • Fail

      Squirrel cage fan blades 1/8" and Exhaust Ductwork free of lint buildup in excess of 1/4", Exhaust fan functional - no steam exiting from tunnel

      • Pass
      • Flag
      • Fail

      All fan belts are present and properly tensioned.

      • Pass
      • Flag
      • Fail

      Combustion blower filter is cleaned daily (gas heated only) or as directed by manufacturer.

      • Pass
      • Flag
      • Fail

      Automatic steam shuts off within 15 seconds of the last garment leaving the steam chamber.

      • Pass
      • Flag
      • Fail

      Steam jets functional.

      • Pass
      • Flag
      • Fail

      Steam tunnel temperature does not exceed 300°F and garment temperature is between 260°F and 290°F (garment target of 270°F). If designed and delivered with a garment temperature probe, the probe must be operational and must be reading within +/- 5 degrees from the test strip check readings.

      • Pass
      • Flag
      • Fail

      Steam heater coils cleaned monthly (steam heated tunnels only)

      • Pass
      • Flag
      • Fail

      No steam or condensate leaks, inspect integrity of pipe insulation intact, and trap wraps

      • Pass
      • Flag
      • Fail

      No air leaks. If no air, N/A.

      • Pass
      • Flag
      • Fail

      Electrical integrity and all panel indicator lights are properly labeled and functioning.

      • Pass
      • Flag
      • Fail

      Inspect fire suppression system integrity (If applicable). Must be inspected annually by qualified outside contractor.

      • Pass
      • Flag
      • Fail

      Housekeeping of steam tunnel ( No water around base, no debris, ensure tunnel external surfaces are clean and free of corrosion and build-up).

      • Pass
      • Flag
      • Fail

      Check inside of tunnel for lint buildup of no more than 1/4", corrosion, no build up of garments/hangers/mother-hooks on floor of tunnel. Inspect exterior of exhaust duct and surrounding roof area. Area should be clean and free of all types of build up.

      • Pass
      • Flag
      • Fail

      Verify that Burner Maintenance is taking place (condition of burner, flame rod, igniter, visual inspection of flame, combustion air blower and intake, visual inspection of gas train). Ensure there are no gas leaks.

      • Pass
      • Flag
      • Fail

      19A Autosort

      All indicator lights are operational & electrical integrity.

      • Pass
      • Flag
      • Fail

      All guards in place

      • Pass
      • Flag
      • Fail

      System air pressure is 6-7 bar (85-100 psig), no air leaks

      • Pass
      • Flag
      • Fail

      Chains are lubricated properly and are not dragging on conveyor tubing. Motors and chains are free of lint buildup, tensioners adjusted properly. System Drive Dogs are in working order with no more than 10% missing and / or no evidence of long-clock alarms. Motor, Gear box and chain drive functioning properly (Not Leaking) as per manufacturer specifications.

      • Pass
      • Flag
      • Fail

      Sacrificial tubing is not worn down to rail, rail discharge switches are not bypassed, gravity rails are free of lint.

      • Pass
      • Flag
      • Fail

      Hanging and Divorce stations inspected for integrity and marry and divorce garments automatically without partner intervention.

      • Pass
      • Flag
      • Fail

      19A.1 LGK Autosort

      All indicator lights are operational & inspected for electrical integrity.

      • Pass
      • Flag
      • Fail

      Chains are lubricated properly and chain guides are in working order. Motors and chains are free of lint buildup, tensioners adjusted properly. System Drive Dogs are in working order with no more than 10% missing and no evidence of garments not flowing smoothly through the system. Motor, Gear box and chain drive functioning properly (Not Leaking) as per manufacturer specifications.

      • Pass
      • Flag
      • Fail

      No air leaks.

      • Pass
      • Flag
      • Fail

      All guards in place and inspected for integrity.

      • Pass
      • Flag
      • Fail

      19B Manual Sorts

      Guards inspected for integrity.

      • Pass
      • Flag
      • Fail

      Motor, Gear box and chain drive functioning properly (Not Leaking) as per manufacturer specifications.

      • Pass
      • Flag
      • Fail

      Rails cleaned and waxed regularly to eliminate excessive wear. Frequency to be determined by observation to see if hung garments slide easily and do not hang up on the rail when expected to move

      • Pass
      • Flag
      • Fail

      Picks calibrated (no excessive garments falling on the floor)

      • Pass
      • Flag
      • Fail

      Rollers and wheels inspected for integrity. No rollers worn through to the metal studs allowed.

      • Pass
      • Flag
      • Fail

      Sorting plates & Teflon plate guides inspected for integrity. No more than 3 retaining pin clips missing per conveyor.

      • Pass
      • Flag
      • Fail

      No air leaks. If no air, N/A.

      • Pass
      • Flag
      • Fail

      Electrical integrity and all panel indicator lights are properly labeled and functioning properly.

      • Pass
      • Flag
      • Fail

      All barcode scanners functional. All Sort+ components functioning as designed. N/A if no barcode scanners in place.

      • Pass
      • Flag
      • Fail

      20 Clean Storage Rail System

      Inspect 20 clean storage trolleys for integrity.

      • Pass
      • Flag
      • Fail

      Check integrity of bearing on switches. If three or more bad bearings are found, deduct points.

      • Pass
      • Flag
      • Fail

      Check incline conveyors for integrity, cleanliness and lint build up

      • Pass
      • Flag
      • Fail

      Check tightness of chain and sprocket condition of incline conveyor per manufacturer specifications.

      • Pass
      • Flag
      • Fail

      Check functionality of all electronic input devices (Buttons, switches). Ensure all components are properly labeled. Electrical integrity.

      • Pass
      • Flag
      • Fail

      Check to ensure chain/sprocket guides & guards are in place, properly holding the chains, and free of gouges.

      • Pass
      • Flag
      • Fail

      Truck loading boom and rail connections (if applicable) inspected for integrity. Structure should not be noticeably bent (possibly from a truck impact) and should line up on both mating points properly. (Consult Corporate Engineer prior to any structural repairs or alterations).

      • Pass
      • Flag
      • Fail

      Check chain tension and lubrication. Check chain drive (motor/gearbox) is operational and is securely anchored. Chain should not show more than 1/4" slack and should show signs of proper lubrication (not over-lubrication).

      • Pass
      • Flag
      • Fail

      Check functionality of boom to ensure it raises and lowers as intended, all lights and indicators working and labeled properly. Electrical integrity.

      • Pass
      • Flag
      • Fail

      Ensure the connector to the shuttle trailer is in proper working condition, no bolts are missing, not dropping trolleys, and the structural integrity of the system is good.

      • Pass
      • Flag
      • Fail

      Check functionality of boom to ensure it raises and lowers as intended, all lights and indicators working properly. Electrical integrity.

      • Pass
      • Flag
      • Fail

      21 Bulk Area - Lift tables, tying equipment, mat rolling equipment

      Ensure they are securely anchored to the floor, that safety guarding is in place and functional agreed upon by engineering and safety (doesn’t inhibit the greasing of the side pivots), grease nipples are fitted and being used on pivot points, the lift arms are level and show no cracked welds/distortion, the lift ram attachment pins are retained in place and show no signs of wear, the hydraulic/air systems are devoid of any leaks, the underside of the table is not used for storage and is free of debris.

      • Pass
      • Flag
      • Fail

      Tying equipment inspected for integrity

      • Pass
      • Flag
      • Fail

      Mat rollers are inspected for mechanical and electrical integrity and proper operation. Mat roller safety light curtains in place and functioning properly. Includes housekeeping and air leaks. No loose or misaligned fingers.

      • Pass
      • Flag
      • Fail

      Mat roller belts and brushes integrity.

      • Pass
      • Flag
      • Fail

      Mat roller safety light curtains in place and functioning properly. This applies to all mat rollers. Refer to OEM or Cintas spec for guidance.

      • Pass
      • Flag
      • Fail

      Productivity equipment inspected for integrity (inspect belts, safety guarding is in place, operator buttons properly labeled, flat conveyor anchored, no exposed wiring)

      • Pass
      • Flag
      • Fail

      21 Bulk Area - Ironers and Spreaders

      Ensure ironers and spreaders are operational and are inspected for integrity.

      • Pass
      • Flag
      • Fail

      Check overall integrity of the ironer chest (pads covers, wax cloths and steam chests are clean and functional)

      • Pass
      • Flag
      • Fail

      Inspect the integrity of the drive systems (belt/chain tension, condition of gears, shaft condition)

      • Pass
      • Flag
      • Fail

      Ensure all guards are intact.

      • Pass
      • Flag
      • Fail

      Vacuum systems are functional.

      • Pass
      • Flag
      • Fail

      If gas fired, verify that Burner Maintenance is taking place (condition of burner, flame rod, igniter, visual inspection of flame, combustion air blower and intake, visual inspection of gas train)

      • Pass
      • Flag
      • Fail

      All Electrical controls, pedals, buttons and indicator lights labeled and functional. Verify all two hand, controls if applicable.

      • Pass
      • Flag
      • Fail

      21 Bulk Area - Small Piece Folder

      Inspect folder for mechanical and electrical integrity. Check housekeeping and safety interlocks

      • Pass
      • Flag
      • Fail

      21 Bulk Area - Towel Bagger

      Inspect mechanical integrity (Conveyor, bag dispenser speed, Bag Sealer, bag shaker, discharge boot) of Towel Bagger.

      • Pass
      • Flag
      • Fail

      Inspect electrical integrity & controls (labels, push buttons, safeties, indicators lights, photo switches, counter accuracy)

      • Pass
      • Flag
      • Fail

      Inspect pneumatic integrity.

      • Pass
      • Flag
      • Fail

      21 Bulk Area - CRT

      Inspect Mechanical Integrity. (to include functionality of threader, feeder, guarding, rollers, conveyors, unwinder).

      • Pass
      • Flag
      • Fail

      Inspect chemical injection integrity.

      • Pass
      • Flag
      • Fail

      Inspect electrical integrity (including all indicator lights and safeties).

      • Pass
      • Flag
      • Fail

      Inspect Utility Integrity (To Include Water, Steam and Air integrity).

      • Pass
      • Flag
      • Fail

      22 Cintas Mat Cleaning System (N/A if no CMCS is in place)

      Parameter placards are properly posted. 30-34 placards.

      • Pass
      • Flag
      • Fail

      Verify that all temperatures and pressures match the posted placards.

      • Pass
      • Flag
      • Fail

      Inspect electrical system (push buttons, conduit, indicators lights, positional switches, and vibration switch in place and functional)

      • Pass
      • Flag
      • Fail

      Water delivery system - ensure there are no leaks in the system and that piping / valve integrity is not compromised by excessive pitting, rust, etc.…..

      • Pass
      • Flag
      • Fail

      Pneumatic system (Check system for leaks, ensure gauges are intact, check regulators and oiler for proper operation)

      • Pass
      • Flag
      • Fail

      Inspect mechanical integrity. Ensure no visible corrosion. Inspect around floor frame and around vacuum section.

      • Pass
      • Flag
      • Fail

      Check the condition of the mat roller belts and/or brushes. Verify mats are rolling properly and roller is in good working order.

      • Pass
      • Flag
      • Fail

      25 Miscellaneous

      Ensure all duct cleaning and inspections, areas performed by qualified outside contractor, to include steam tunnel, all dryers, gas fired pressing equipment, and CMCS. Review the contractor report. Refer to MaintainX task 0353 and 0354.

      • Pass
      • Flag
      • Fail

      Any Inoperable Equipment: - all equipment must be covered (If Outside) - all equipment inside must be tagged and locked OOS - no long term (longer than 4 months) equipment storage - Within 4 months equipment must be repaired or disposed through proper Asset Disposal Procedures. Policy C-27 is the reference for this

      • Pass
      • Flag
      • Fail

      Inspect a random sampling of 4 carts from each department for integrity (check casters, spring-bottoms functional, no fiberglass shards exist that can puncture a partner's skin, for metal carts ensure no stray cage wire is out of place that may injure a partner).

      • Pass
      • Flag
      • Fail

      General housekeeping in and around plant equipment not already covered in previous line items. Ex: of issues that would result in a loss of points are: corroded mounting hardware and skid stands, standing water; equipment that is excessively dirty so that it is difficult to see the paint on the asset; product / trash should not be on equipment; there should no buildup of lint/dust more than 1/4" on any equipment or roof structure. This includes the Maintenance Shop housekeeping.

      • Pass
      • Flag
      • Fail

      Any electrical panel (Including Control Panels, & Transformers) in a location should be clean and free of debris, labeled, in good wiring order and include wireways and caps/covers. Ensure push buttons, conduit, indicators lights, positional switches, & vibration switch in place and functional. Ensure MX standard electrical distribution tasks are completed as required: Refer to MX Task 0109 (Annual), 0418 (Every 5yrs), 0419 (Every 2yrs).

      • Pass
      • Flag
      • Fail
    Source: 24P DC Columbus - Cintas (Community Member)

    Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.