Folder Gluer Autonomous Maintenance
To establish the Leary Glue System PM work instructions for Folder/Gluer operations. This
Work Instruction applies to Hayesville but can be used at all Rohrer Corporation facilities.
Folder Gluer Autonomous Maintenance
To establish the Leary Glue System PM work instructions for Folder/Gluer operations. This
Work Instruction applies to Hayesville but can be used at all Rohrer Corporation facilities.
TOOLS NEEDED TO COMPLETE
Count the number of guns to be cleaned (typically with valves left open- guns 1, 2 and 3 in photo below). Add two to that count for the pail count. Leave one pail empty and fill the rest with hot water. Move all items collected to the gluer.
LIST NUMBER OF BUCKETS USED
YOU WILL GET COVERED IN GLUE IF YOU DO NOT DO THIS SECTION
Dispose the water from the pails per regulations. Clean the pails and return them to the storage area.