Back

SDC - Annual Preventative Maintenance

Annual preventative maintenance activities for the SDC.
Expal USA
01/14/2026

SDC - Annual Preventative Maintenance

This procedure outlines the annual preventative maintenance tasks required to inspect, service, and verify proper operation of the SDC. Completing these checks helps ensure equipment reliability, safety, and continued compliance with operational requirements.

    Loading System

    Inspection of the conveyor system.

    Inspect conveyor motor 101-M01

    Inspect conveyor motor 101-M02

    Inspect Turn Table motor 102-M01

    Inspect Elevator motor 104-M01

    Inspect Elevator motor 104-M02

    Inspect signal lamp YI-10704

    Loading Gate

    Inspect Loading Gate for wear

    • Pass
    • Flag
    • Fail

    Inspect Loading gate cylinders (2)

    • Pass
    • Flag
    • Fail

    Inspect Pneumatic Seals

    • Pass
    • Flag
    • Fail

    Loading Chamber

    Inspect Chute

    • Pass
    • Flag
    • Fail

    Visual inspection of chamber

    • Pass
    • Flag
    • Fail

    Inspect Pusher

    • Pass
    • Flag
    • Fail

    Inspect Tilt Cradle Cylinders A/B

    • Pass
    • Flag
    • Fail

    Inspect Frag-valve Cylinder

    • Pass
    • Flag
    • Fail

    Inspect Frag-valve Pin

    • Pass
    • Flag
    • Fail

    Inspect Emergency Pusher

    • Pass
    • Flag
    • Fail

    Inspect Tilt Cradle Sprocket/Chain

    • Pass
    • Flag
    • Fail

    Inspect Process Ventilation Valve

    • Pass
    • Flag
    • Fail

    DC

    Visual inspection of DC for damage

    • Pass
    • Flag
    • Fail

    Visual inspection of locking ring

    • Pass
    • Flag
    • Fail

    Inspection of heating elements.

    • Pass
    • Flag
    • Fail

    Inspection of heating element connections

    • Pass
    • Flag
    • Fail

    Combustion Air

    Check insulation resistance of the heating elements.

    • Pass
    • Flag
    • Fail

    Check heating element connections.

    • Pass
    • Flag
    • Fail

    Checking piping for leakage/damage.

    • Pass
    • Flag
    • Fail

    Check valve 140V01 for leakage/damage.

    • Pass
    • Flag
    • Fail

    Check valve UV-14001 for function and leakage/damage.

    • Pass
    • Flag
    • Fail

    Lifting System

    Visual inspection of leakage/damage (UV12012)

    • Pass
    • Flag
    • Fail

    Measure thickness of the rotors on brakes for lifting unit. (UV12017)

    Measure air gap of the brakes for lifting unit. (UV12017)

    Measure operating voltage for brakes on the lifting unit. (UV12017)

    Hydraulic Unit (180)

    Process Ventilation

    Check coupling/fitting for leaks

    • Pass
    • Flag
    • Fail

    Check/clean fan rotor

    • Pass
    • Flag
    • Fail

    Check Motor 172-M01 for damage.

    • Pass
    • Flag
    • Fail

    Air Manifolds

    check the third-floor air manifold for leaks.

    • Pass
    • Flag
    • Fail

    check the second-floor air manifold for leaks.

    • Pass
    • Flag
    • Fail

    Control room/Surveillance

    All equipment function as intended.

    • Pass
    • Flag
    • Fail

    Camera and housing (YI-11401)

    • Pass
    • Flag
    • Fail

    Camera and Housing (YI-11405)

    • Pass
    • Flag
    • Fail

    Camera and housing (YI-12023)

    • Pass
    • Flag
    • Fail

    Electrical Room

    Visual Inspection for damage

    • Pass
    • Flag
    • Fail

    Check cabinet doors for damage/tightness.

    • Pass
    • Flag
    • Fail

    Marking/labels

    • Pass
    • Flag
    • Fail

    Warning signs

    • Pass
    • Flag
    • Fail

    Other

    Stairs/platforms for damage

    • Pass
    • Flag
    • Fail

    Special tools needed for SDC (Inventory of tools)

    • Pass
    • Flag
    • Fail
Source: Expal USA (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.