Back

AGB PART ROTATION CALIBRATION (QA-CAL.0016_REV 002)

QA-CAL.0016_REV 002:Verify/calibrate the Part Rotation Speeds (High & Low) on the AGB Machines. Checklists can help to save time and money by assisting with the early detection and resolution of potential difficulties.
Ellisville - Quality
06/03/2025

AGB PART ROTATION CALIBRATION (QA-CAL.0016_REV 002)

QA-CAL.0016_REV 002:Verify/calibrate the Part Rotation Speeds (High & Low) on the AGB Machines. Checklists can help to save time and money by assisting with the early detection and resolution of potential difficulties.

    Equipment Information:

    Equipment ID:

    Calibration Control Number:

    Calibration Procedure:

    1. ATTACH CONE SHAPED ATTACHMENT TO THE TACHOMETER. 2. REMOVE THE PART BOOT FROM THE SPINDLE. 3. FROM THE MAIN MENU, GO TO “SYSTEM SPEEDS”. 4. CHANGE THE “JOG PART ROTATION SPEED” TO 16 RPM FOR LOW RANGE OR 28 RPM FOR HIGH RANGE. 5. GO TO “MANUAL JOG” SCREEN AND ENABLE JOG. 6. WHILE ONE PERSON HOLDS THE TACHOMETER STILL AND STRAIGHT IN THE TOP OF THE SPINDLE, ANOTHER PERSON SHOULD HOLD THE “PART ROTATION” FOR A MINIMUM OF 3 ROTATIONS. 7. RELEASE “PART ROTATION” AND RECORD THE RPM ON THE PART ROTATION CALIBRATION WORKSHEEET. 8. REPEAT STEPS 6 & 7 TWICE MORE. 9. REPLACE THE PART BOOT AND RETURN THE MACHINE TO PRODUCTION.

    AS FOUND - CALIBRATION RESULTS

    LOW RANGE SPINDLE SPEED:

    PASS 1 (RPM)

    MINIMUM = 14.4 RPM MAXIMUM = 17.6 RPM

    PASS 2 (RPM)

    MINIMUM = 14.4 RPM MAXIMUM = 17.6 RPM

    PASS 3 (RPM)

    MINIMUM = 14.4 RPM MAXIMUM = 17.6 RPM

    AVERAGE (RPM)

    MINIMUM = 14.4 RPM MAXIMUM = 17.6 RPM

    PASS OR FAIL:

    • Pass
    • Flag
    • Fail

    HIGH RANGE SPINDLE SPEED:

    PASS 1 (RPM)

    MINIMUM = 25.2 RPM MAXIMUM = 30.8 RPM

    PASS 2 (RPM)

    MINIMUM = 25.2 RPM MAXIMUM = 30.8 RPM

    PASS 3 (RPM)

    MINIMUM = 25.2 RPM MAXIMUM = 30.8 RPM

    AVERAGE (RPM)

    MINIMUM = 25.2 RPM MAXIMUM = 30.8 RPM

    PASS OR FAIL:

    • Pass
    • Flag
    • Fail

    AS LEFT - CALIBRATION RESULTS

    LOW RANGE SPINDLE SPEED:

    PASS 1 (RPM)

    MINIMUM = 14.4 RPM MAXIMUM = 17.6 RPM

    PASS 2 (RPM)

    MINIMUM = 14.4 RPM MAXIMUM = 17.6 RPM

    PASS 3 (RPM)

    MINIMUM = 14.4 RPM MAXIMUM = 17.6 RPM

    AVERAGE (RPM)

    MINIMUM = 14.4 RPM MAXIMUM = 17.6 RPM

    PASS OR FAIL:

    • Pass
    • Flag
    • Fail

    HIGH RANGE SPINDLE SPEED:

    PASS 1 (RPM)

    MINIMUM = 25.2 RPM MAXIMUM = 30.8 RPM

    PASS 2 (RPM)

    MINIMUM = 25.2 RPM MAXIMUM = 30.8 RPM

    PASS 3 (RPM)

    MINIMUM = 25.2 RPM MAXIMUM = 30.8 RPM

    AVERAGE (RPM)

    MINIMUM = 25.2 RPM MAXIMUM = 30.8 RPM

    PASS OR FAIL:

    • Pass
    • Flag
    • Fail

    TEST EQUIPMENT INFORMATION:

    TEST EQUIPMENT CONTROL NUMBER:

    TEST EQUIPMENT SERIAL NUMBER:

    TEST EQUIPMENT CALIBRATION DUE DATE:

    APPROVAL INFORMATION:

    MAINTENANCE TECHNICIAN:

    CALIBRATION COMPLETION DATE:

    CALIBRATED BY:

    TECHNICIAN SIGNATURE:

    Click here to sign

    QUALITY PERSONNEL:

    APPROVED BY:

    APPROVAL SIGNATURE:

    Click here to sign

    APPROVAL DATE:

Source: Ellisville - Quality (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.