Back

5130 Preventive Maintenance Procedure

This procedure covers critical safety and performance checks, including testing the emergency stop (E-stop) for proper functionality, inspecting the heat sink for cleanliness and adequate cooling, and verifying coolant levels are within operational limits. These steps help ensure the equipment runs safely, prevents overheating, and reduces the risk of unplanned downtime.
Vertiv Lincoln
08/15/2025

5130 Preventive Maintenance Procedure

This procedure covers critical safety and performance checks, including testing the emergency stop (E-stop) for proper functionality, inspecting the heat sink for cleanliness and adequate cooling, and verifying coolant levels are within operational limits. These steps help ensure the equipment runs safely, prevents overheating, and reduces the risk of unplanned downtime.

    Check Estop for functionality

    • Pass
    • Flag
    • Fail

    Heat sink (Cold Plate)

    Check coolant level. Rifrost

    • Pass
    • Flag
    • Fail

    Clean fans and coils on A/C units and clean electrical cabinets

    Clean and lubricate press beam Y axis guide rails and rollers. WD-40, Kluber GB00, Mobilux EP2

    Clean and lubricate backgauge axis's, rails, and ballscrew. WD-40, Kluber GB00, Mobilux EP2

    Clean and lubricate I Axis surfaces for spacers. Shell 220

    Change hydraulic oil filter. Mat# 1801553

    Perform visual inspection of hydraulic hoses, fittings, valves, tank, and pump for leaks.

    • Pass
    • Flag
    • Fail

    Visually inspect hydraulic cylinders for leaks or damage

    • Pass
    • Flag
    • Fail

    Drain water from compressed air make up unit

    • Pass
    • Flag
    • Fail

    Replace air make up unit filter.

    Perform visual inspection of backgauge components for any damage. Repair or make follow up W.O.

    • Pass
    • Flag
    • Fail

    Perform visual inspection of energy chain and all cables and hoses that run within the chain. Repair or make follow up W.O.

    • Pass
    • Flag
    • Fail

    Replace back up battery yearly

Source: Vertiv Lincoln (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.