AMX23-05 Monthly Calibration
This monthly calibration procedure verifies that all power supply and pin voltages on the AMX23-05 system are within specified tolerances using a calibrated meter. Completing this calibration helps maintain accurate machine operation, supports product quality, and identifies electrical issues before they cause downtime.
AMX23-05 Monthly Calibration
This monthly calibration procedure verifies that all power supply and pin voltages on the AMX23-05 system are within specified tolerances using a calibrated meter. Completing this calibration helps maintain accurate machine operation, supports product quality, and identifies electrical issues before they cause downtime.
Calibration Procedure
40. Measure the voltage at the 24.00vdc power supply. (23vdc - 25vdc)
Meter name
Unit
50. Measure the voltage at the 7.10vdc power supply. (6.9vdc - 7.3vdc)
Meter name
Unit
70. Connect the red meter lead to pin 1. (11.2vdc - 11.6vdc)
Meter name
Unit
80. Connect the red meter lead to pin 2. (9.5vdc - 10.5vdc)
Meter name
Unit
90. Connect the red meter lead to pin 3. (9.3vdc - 9.7vdc)
Meter name
Unit
100. Connect the red meter lead to pin 4. (7.7vdc - 8.1vdc)
Meter name
Unit
110. Connect the red meter lead to pin 5. (1.08vdc - 1.32vdc)
Meter name
Unit
120. Connect the red meter lead to pin 6. (10vdc - 12vdc)
Meter name
Unit
130. Connect the red meter lead to pin 7. (8.8vdc - 9.2vdc)
Meter name
Unit
140. Connect the red meter lead to pin 8. (3.8vdc - 4.2vdc)
Meter name
Unit
190. Enter the ID# of the voltage meter that was used.
200. Sign Off
Click here to sign
Source: TAC Manufacturing (Community Member)