This procedure guides the monthly voltage calibration check of the CYE17-05 machine's power supplies.
TAC Manufacturing
12/10/2025

CYE17-05 Monthly Calibration

This procedure covers the monthly calibration of the CYE17-05 machine, measuring the 24VDC, 12VDC, 14VDC, and 8VDC power supplies against their tolerance ranges using a calibrated voltage meter. If all readings pass, a calibration sticker is applied; if not, a work order is created and coordinated with Maintenance Management, with the meter ID and any changes recorded before sign-off.

    Calibration Procedure

    40. Measure the voltage at 24.00vdc power supply. (23.8vdc - 24.2vdc)

    • CYE17-0540.PNG
    Meter name
    Unit

    50. Measure the voltage at 12.00vdc power supply. (11.8vdc - 12.2vdc)

    • CYE17-0550.PNG
    Meter name
    Unit

    60. Measure the voltage at 14.00vdc power supply. (13.8vdc - 14.2vdc)

    • CYE17-0560.PNG
    Meter name
    Unit

    70. Measure the voltage at 8.00vdc power supply. (7.8vdc - 8.2vdc)

    • CYE17-0570.PNG
    Meter name
    Unit

    110. Enter the ID# of the voltage meter that was used.

    120. Sign Off

    Click here to sign

Source: TAC Manufacturing (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.