  • Hydraulic Return Filter, Breather & Strainer - Check, Change

  • WARNING:Hot oil and components can cause personal injury. Do not allow hot oil or components to contact skin.

  • Park the lift truck level with the forks lowered, parking brake engaged, transmission in NEUTRAL and the engine stopped.

  • 64.PNG
  • 65.PNG
  • Transmission Oil, Oil Filter & Strainer - Check, Clean, Change

  • Lift Chains - Test, Check, Adjust

  • Lift Chain Wear Test

  • Chain wear test is a measurement of wear of the chain links and pins. Take the following steps to check chain wear.

  • 66.PNG
  • 67.PNG
  • Check for Equal Tension

  • WARNING:Personal injury can be caused by sudden movement of the mast and carriage. Keep hands and feet clear of any parts that can move.

  • Lift Chain Adjustment

  • NOTE: If carriage height is not correct, make adjustments by following procedures.

  • Carriage Chain Adjustment

  • NOTE: See the previous section, “Carriage Roller Extrusion” in “When Required” for proper height of carriage.

  • 70.PNG
  • Mast Chain Adjustment - FF, FFT Mast

  • NOTE: See the previous section, “Carriage Roller Extrusion” in “When Required” for proper inner mast height.

  • 72.PNG
  • Air Intake System - Change

  • Changing Primary Element

  • Changing Secondary Element

  • NOTICE Always replace the secondary element. Do not attempt to reuse it by cleaning.

  • 73.PNG
  • NOTICE : Always replace the secondary element. Do not attempt to reuse it by cleaning.

  • Inspect Coolant Hoses (LP, Dual Fuel Engine Only)

Source: Doosan

Please note that any procedure, checklist, or other document available in the MaintainX Global Procedure Library is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.