LDA Driver Verification (ECCO Safety Group - Boise)
Verifying torque driver accuracy helps make sure every fastener is tightened to spec and product quality stays consistent.
LDA Driver Verification (ECCO Safety Group - Boise)
This procedure checks the LDA torque drivers by taking readings at 5, 2 and 4 in·lb and confirming that each one is within ±0.5 in·lb. If a reading is out of tolerance, the technician adjusts the driver, retests and records the new reading, and contacts a supervisor or maintenance technician if help is needed.
5 IN*LB (Tolerance +/- 0.5)
Meter name
Unit
if the answer is "> 5.5 "
Out Of Tolerance
Torque Drivers: adjust with tool. Soldering Irons: replace tip If help is needed contact your Supervisor or Maintenance Technician.
5 IN*LB (Tolerance +/- 0.5)
Meter name
Unit
if the answer is "< 4.5 "
Out Of Tolerance
Torque Drivers: adjust with tool. Soldering Irons: replace tip If help is needed contact your Supervisor or Maintenance Technician.
5 IN*LB (Tolerance +/- 0.5)
Meter name
Unit
2 IN*LB (Tolerance +/- 0.5)
Meter name
Unit
if the answer is "> 2.5 "
Out Of Tolerance
Torque Drivers: adjust with tool. Soldering Irons: replace tip If help is needed contact your Supervisor or Maintenance Technician.
2 IN*LB (Tolerance +/- 0.5)
Meter name
Unit
if the answer is "< 1.5 "
Out Of Tolerance
Torque Drivers: adjust with tool. Soldering Irons: replace tip If help is needed contact your Supervisor or Maintenance Technician.
2 IN*LB (Tolerance +/- 0.5)
Meter name
Unit
4 IN*LB (Tolerance +/- 0.5)
Meter name
Unit
if the answer is "> 4.5 "
Out Of Tolerance
Torque Drivers: adjust with tool. Soldering Irons: replace tip If help is needed contact your Supervisor or Maintenance Technician.
4 IN*LB (Tolerance +/- 0.5)
Meter name
Unit
if the answer is "< 3.5 "
Out Of Tolerance
Torque Drivers: adjust with tool. Soldering Irons: replace tip If help is needed contact your Supervisor or Maintenance Technician.
4 IN*LB (Tolerance +/- 0.5)
Meter name
Unit
Source: ECCO Safety Group - Boise (Community Member)