pH Sampling Waste Water
This procedure is used to measure and record wastewater pH within the permitted time window so each sampling event meets the discharge permit requirements.
pH Sampling Waste Water
This procedure outlines the field measurement of wastewater pH at the permit sampling point using a calibrated handheld pH meter during each sampling event. It guides the technician through the pre-start meter and PPE checks, 3-point calibration, sample collection and reading of pH and temperature, meter cleaning and storage, and recording the results on the chain of custody.
Procedure Max Score: 21
Notes:
Pre-Start Equipment Check
Calibration
Required by Chesterfield County
Sampling Process at Manhole #2
Cleaning & Storage
Chain of Custody
Source: Plenty-VA (Community Member)