This procedure provides step-by-step guidance for inspecting, testing, and troubleshooting burner power, electrical circuits, sensors, solenoids, relays, and ignition components. It helps technicians safely diagnose voltage, continuity, and control issues to ensure proper burner operation and reliable ignition performance.
Burner Power Electrical and Ignition Troubleshooting Guide
This procedure provides step-by-step guidance for inspecting, testing, and troubleshooting burner power, electrical circuits, sensors, solenoids, relays, and ignition components. It helps technicians safely diagnose voltage, continuity, and control issues to ensure proper burner operation and reliable ignition performance.
Check Power:
Burner Plug:
From the Burner Plug to PAKSTAT/Battery:
The burner Solenoid Pre-2020:
Current Burner Relay. (This replaced the solenoid):
HTO/ Material PAKSAT:
RTD sensors to the PAKSTATS:
Testing the Burner Solenoid:
Testing the DC controller:
Burner Ignition Coil:
Fuel Solenoid Test:
Bleed the Burner:
Burner Fuel Line Collapsing:
New burner Replacement (only dual fuel Lines)