This procedure ensures the Nylon Patch 5 Line operates safely and reliably by verifying the condition of its key components on a monthly basis.
H.B Fuller Co. - Northbrook IL
02/05/2026

Monthly Patch 5 Preventive Maintenance

This procedure outlines the monthly maintenance tasks for inspecting and ensuring the proper functioning of the Nylon Patch 5 Line, including the feeder bowl, induction heater, air lines, powder return system, drive mechanism, safety guards, electrical panel, and conveyor system.

    Feeder Bowl Inspection

    Inspect the Feeder Bowl for Cracks

    • Pass
    • Flag
    • Fail

    Inspect all Speed and controls units

    • Pass
    • Flag
    • Fail

    Vibrators Check

    Check that the Vibrators are working correctly

    • Pass
    • Flag
    • Fail

    Air Lines and Regulators Inspection

    Inspect the Air lines and regulators for any replacements needed

    • Pass
    • Flag
    • Fail

    Drive Mechanism and Speed Controls

    Inspect the condition of the Drive mechanism (belts and chain)

    • Pass
    • Flag
    • Fail

    Inspect the modulation controls from the speed control units

    • Pass
    • Flag
    • Fail

    Machine Safety Guards Check

    Check the integrity of the machine safety guards

    • Pass
    • Flag
    • Fail

    Inspect all joints (bolts and nuts)

    • Pass
    • Flag
    • Fail

    Main Electrical Panel Inspection

    Inspect the Main Electrical Panel

    • Pass
    • Flag
    • Fail

    Check the Line for exposed/burnt wiring

    • Pass
    • Flag
    • Fail

    Inspect the Condition of the Band wheels & Dry Conveyor System

    Belts, wheels checks for wear & tear

    • Pass
    • Flag
    • Fail

    Check tightness of bolts & nuts in sequence

    • Pass
    • Flag
    • Fail

    Inspect the Induction Heater

    Inspect for leaks

    • Pass
    • Flag
    • Fail

    Check for loose/burnt ground Wires

    • Pass
    • Flag
    • Fail

    Blow out Unit with compressed Air and clean out filters

    • Pass
    • Flag
    • Fail

    Powder System

    Inspect filter bag for material consistency

    • Pass
    • Flag
    • Fail

    check air inlets and components

    • Pass
    • Flag
    • Fail
Source: H.B Fuller Co. - Northbrook IL (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.