Back

Portable Miller Fume Extractor - Semi Annual

A semi-annual inspection and servicing of the portable Miller fume extractor to evaluate filtration media, airflow capacity, and overall unit condition, ensuring consistent fume extraction performance and a safe breathing environment for operators.
Oshkosh Defense - Harrion St
07/21/2026

Portable Miller Fume Extractor - Semi Annual

This procedure provides instructions for performing the semi-annual inspection and maintenance of the Portable Miller Fume Extractor to ensure it remains clean, safe, and fully operational. It includes inspection of the filter, spark guard, hoses, and electrical components, as well as cleaning, final operational checks, and technician sign-off.

    Preparation

    * Safety Glasses * Steel Toe boots / shoes * Hearing Protection (if required in area) * Appropriate gloves (as necessary) * Lock Out / Tag Out (as necessary)

    Rags Cleaning solution Filter - 300450 - Airgas Portable vacuum cleaner with HEPA Filter

    Procedure / Inspection

    Inspect main filter for damage, wear or clogging

    Flag = Filter is dirty but able to be cleaned (less than 30 mins) Fail = Filter had to be replaced (part had to be ordered)

    • Pass
    • Flag
    • Fail

    Inspect spark guard for broken or damaged wires

    • Pass
    • Flag
    • Fail

    Inspect flexible hosing / boots for cracks, wear or damage

    Flag = wear noticed, (repair less than 30 mins) Fail = Hosing/boots need to be replaced, (longer than 30 mins)

    • Pass
    • Flag
    • Fail

    Inspect electrical plug-in and cable for damage or wear

    Flag = wear noticed, (repair less than 30 mins) Fail = Larger repair requiring an electrician (longer than 30 mins)

    • Pass
    • Flag
    • Fail

    Final Checks

    * Re-install any Panels or components that were removed during Maintenance * Remove Lockout Tagout per Lockout Procedure (as necessary) * Energize all power sources (as necessary) * Return equipment to Operational status (as necessary) * Visually confirm that equipment powered on as intended

    Technician Signature

    By signing this form, you acknowledge that you have completed the Work Order to the best of your ability.

    Click here to sign
Source: Oshkosh Defense - Harrion St (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.